Handu Package Hirox Microscope DVIA-MO1000 (P20) Vibration Environment Measurement — May 2, 2016

MO1000_P20 vibration-environment worksheet measured at Handu Package (Namdong Industrial Complex, Incheon) on 2016-04-30 for a Hirox microscope after platform installation. Published: workstation photograph after the Handu Package subtitle, equipment-related image, floor vs platform VC grades, triaxial VC curves, MO1000 internal-program transmissibility (~−30 dB in all directions), and an active-operation photograph. The top title-banner raster is omitted.

Hitachi SEM SU3500 DVIA-MB1000 (MB1000 P12) China business trip worksheet — 2016.04.08

Korean workbook for MB1000 program P12 covering a China site visit (2016-04-05~2016-04-07) for a Hitachi SEM SU3500, written 2016-04-08 by Choi, Hyoung Mun and Lim, Jong-wook. Published figures follow DOCX §2a: installation photograph after the target-equipment line (image2), MB1000 internal-program Z/X/Y (image3–5), vibration-environment Z/X/Y (image6–8), SEM imaging OFF vs ON (image9–10), JEOL 2100F discussion materials (image11–12), and FEI TEM consultation figures (image13–15). Decorative title-strip bitmap (image1) is omitted. The source has no Vibration specification, Measurement Summary template, or Generic Vibration Criteria section; none were added.

DVIA-M type (MB1000) Installation test — NEMO — 2016-04-08
Installation Report
DVIA-M Series
04-08-2016

DVIA-M type (MB1000) Installation test — NEMO — 2016-04-08

MB1000 handout DVIA-M type (MB1000) Installation Test Report to Nemo (installation and measurement on 2016-04-06, reporting on 2016-04-08 by LIM JONG UK, Daeil Systems). The Installation Results Summary text and bullets follow the DOCX extract; plotted figures publish in DOCX §2a paragraph order — internal-program transmissibility (rId6–8 → images 1–3), PULSE 1/3-octave (rId9–11 → images 4–6), and Image Check ACTIVE OFF/ON (rId12–13 → images 7–8).

Hitachi SU3500 SEM DVIA-MB1000 Installation
Installation Report
DVIA-M Series
04-06-2016

Hitachi SU3500 SEM DVIA-MB1000 Installation

Hitachi SU3500 SEM DVIA-MB1000 Installation

Hitachi SU8010 SEM DVIA-MB1000 Installation
Installation Report
DVIA-M Series
04-06-2016

Hitachi SU8010 SEM DVIA-MB1000 Installation

Hitachi SU8010 SEM DVIA-MB1000 Installation

Tier-1 Semiconductor DVIA-MB3000 P5 vibration survey — Hwaseong NRD Building (2016.03.30)

Post-installation vibration survey for a DVIA-MB3000 P5 platform at Tier-1 Semiconductor (Hwaseong, NRD building, 6th floor) on 30 March 2016. VC-class summary for floor versus platform top, narrative assessment, equipment allowable vibration criterion diagrams (vertical and horizontal), and VC-class environment curves for Z, X, and Y. Reference uses the standard Generic Vibration Criteria markdown table only.