Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

Hitachi SU8010 DVIA-MB1000 (MB1000 P15) vibration environment measurement — Seoul National University of Science and Technology — 2016-01-12
2016 workbook for MB1000 program P15 (channel partner worksheet) measuring the vibration environment for a Hitachi SU8010 SEM at Seoul National University of Science and Technology (Hyeseong Hall, 2F electron microscopy lab). Published items follow Word §2a embed order after the omitted first-paragraph banner: equipment photograph, VC-CLASS floor vs isolation-top summary and Z/X/Y environment curves, then Z/X/Y built-in-program screenshots with transmissibility and autospectrum (table probe) captures. Separate “Autospectrum (floor)” placeholders appear in plaintext only; no fourth embedded figure per axis was present under word/media.

HITACHI SEM SU8010 DVIA-MB1000 program P14 — Giheung vibration survey (2015-12)
MB1000 internal program P14 vibration survey for a Hitachi SU8010 SEM after passive isolation installation at a Giheung semiconductor test laboratory (2015-12-07, DAEIL SYSTEMS Jong-wook Lim). Published: target tool imagery, Z/X/Y VC-Class environment curves, per-axis built-in program captures (transmissibility and autospectrum of table), and PASSIVE vs ACTIVE SEM images.

Quanta FEI FEG250 SEM DVIA-MB1000 — China business trip report (MB1000 P13, October 2015)
Workbook dated 2015.10.30 for MB1000_P13 setup targeting a Quanta FEG250 SEM (travel 15.10.26–15.10.29, travelers Choi / Lim). Figures follow DOCX §2a: photograph after title + equipment line (image2), MB1000 internal-program Z/X/Y stacks (nine bitmaps incl. opening Z-axis view; the text line “Autospectrum of Floor” appears under Y with no matching extra `media/` image), 진동환경 Z/X/Y (image12–14), SEM comparison table at Active 300 k× / 520 k×, Passive 520 k×, and Floor 520 k× (image15–18.jpeg). Decorative title-strip bitmap image1 omitted. Source has no Reference / Generic VC table — none added.

DVIA-M type (MB1000) installation test report — Nemo — 2015-10-30
MB1000 installation test worksheet for Nemo (measurement 2015-10-28, reported 2015-10-30 by DAEIL SYSTEMS • LIM JONG UK): VC-Class summary on floor versus active top, narrative bullets including FEI Korea site-readiness context, and fifteen figures — Result 1 internal-program transmissibility plus autospectrum-of-table and autospectrum-of-floor for Z/X/Y; Result 2 PULSE 1/3-octave Z/X/Y; Result 3 PULSE g-data Z/X/Y. Decorative title/header-only graphics from the Word handout are not published.
Tier-1 Semiconductor MB3000 P2 Cheongju vibration environment measurement — 2015.10.16
Post-installation vibration survey for MB3000 at Tier-1 Semiconductor (Cheongju Fab 1, P&T2 analysis laboratory, 4th floor): VC-CLASS summary for floor vs platform top and vertical (Z) and horizontal (X, Y) VC curves. Engineer Jong-wook Lim (DAEIL SYSTEMS), measurement date 16 October 2015.

KRICT Building 10 L3 EMI room DVIA-MB3000 vibration environment measurement (September 2015)
Post-install vibration survey at Korea Research Institute of Chemical Technology comparing floor vs DVIA-MB3000 top plate in VC-Class for Z/X/Y axes, including annotated BASE/TOP locations and 1/3-octave velocity curves.