Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

TESCAN SOLARIS GMH DVIA-M1000 (230501R3-5) Set up — Shenzhen
DVIA-M1000 (serial 230501R3-5) set-up report for TESCAN SOLARIS GMH in Shenzhen. Overview states the active vibration isolation platform is appropriately installed and functioning as intended. Internal program performance screenshots are provided for the Z, X, and Y axes; cover-only artwork is not published.

Crossbeam550 DVIA-M1000 (230522R2) Set up — Shenzhen
DVIA-M1000 (serial 230522R2) set-up report for Crossbeam550 in Shenzhen (PXW). Overview states the active vibration isolation platform is appropriately installed and functioning as intended. Internal program performance screenshots are provided for the Z, X, and Y axes; cover-only artwork is not published.

Southwest Jiaotong University SEM5000 DVIA-M1000 (230209R2) Installation Report
DVIA-M1000 abbreviated worksheet (serial 230209R2). Setup and reporting dated 23.09.18; measurement date 2023.09.18 (Monday) in Chengdu with operator Jongwon Park from DAEIL SYSTEMS. END USER Southwest Jiaotong University; target equipment SEM5000 and installation site Chengdu as in the form. The Overview states the standard DVIA-M1000 sentence only. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. The internal-program section title reads “M1000 internal program performance measurement result”; published figures are three program plots labeled Z axis, X axis, and Y axis. Decorative title-band and pre-checklist scene imagery from the Word file are omitted from public copy.

Thermofisher Quattro S DVIA-M1000 (230116R3) Installation Report
DVIA-M1000 installation report (serial 230116R3) for a Thermofisher Quattro S system at Jinan for QILU Pharmaceutical Co., Ltd. The overview states the DVIA-M1000 platform is appropriately installed and functioning as intended; published figures are M1000 internal program performance screenshots for Z, X, and Y axes.

Hefei Institutes of Physical Science (CAS) Sigma300 DVIA-U1000 (230515R1) Installation Report — Hefei
DVIA-U1000 compact worksheet (serial 230515R1) for ZEISS Sigma300 at Hefei Institutes of Physical Science, Chinese Academy of Sciences. Setup and reporting 23.09.11–23.09.15; measurement 2023.09.11 (Monday); operator Lee, Youngha; business trip 17.12.27~17.12.29. Published U1000 internal-program Z/X/Y screenshots only—the issued Word file has no separate equipment setup raster after the omitted header banner, no Octave Band / Active Off–On plots, and no separate Reference VC figure.

Shanghai Liyi Aluminum Apreo 2C HiVac DVIA-M1000Y (230602R2) Installation Report
DVIA-M1000Y abbreviated worksheet (serial 230602R2; source M1000Y_230602R2_23.08.23.docx). Date of setup 23.08.23 and date of reporting 23.09.14; measurement date 2023.08.23 (Wednesday) in shanghai with operator Sangjae Lee from DAEIL SYSTEMS. END USER Shanghai Liyi Aluminum Co.,Ltd.; target equipment Apreo 2C HiVac and place of installation shanghai as in the form. The Overview sentence matches the issued wording for DVIA-M1000Y. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. The internal-program section title reads “M1000Y internal program performance measurement result”; published figures are three plots under Z axis, X axis, and Y axis. Decorative header raster under the company line and the bitmap under “(M1000Y_230602R2 Set up)” are omitted from public copy.