Tier-1 Semiconductor Chengdu ZEISS GeminiSEM 360 DVIA-M1000 (231204R6) Installation Report — 2024.07.12
DVIA-M1000 serial 231204R6 worksheet for ZEISS GeminiSEM 360 SEM at Tier-1 Semiconductor Chengdu, with setup and reporting on 2024.07.12. The issued form publishes the overview text, site lines, GeminiSEM identification, Chaewon Lee (DAEIL SYSTEMS), and internal-program performance plots labeled Vertical, Left to Right, and Front to Back. Decorative masthead-only graphics above the worksheet title block are omitted from the public gallery.

YIMO TCL ZEISS SEM Sigma360 DVIA-M1000 (240517R5) Installation Report
DVIA-M1000 installation report (serial 240517R5) for ZEISS SEM Sigma360 via YIMO. Overview matches the published form. Equipment condition: The equipment is installed. Published figures include UI-program plots as listed; Reference uses the standard Generic Vibration Criteria markdown table.

Shanghai Jiaotong University Thermo Fisher Apreo 2S DVIA-MB1000 (210701R6) Installation Report — 2024.07.06
DVIA-MB1000 abbreviated MB1000 worksheet (serial 210701R6 in the issued title line). Setup dated 24.06.24 and reporting dated 24.07.06; measurement date 2024.06.24 (Monday) at Shanghai Jiao Tong University with operator Byeonghun Cho from DAEIL SYSTEMS. END USER reads “Shanghai” on the checklist table; Thermo Fisher Apreo 2S FE-SEM and installation site Shanghai Jiaotong University match the Target equipment / Place of installation rows. The Overview carries the DVIA‑MB1000 standard sentence plus equipment bullets as printed. No vibration isolation system table, vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. The MB1000 internal program section publishes three plots under Vertical, Left to Right, and Front to Back. Decorative centered header/table layout text from Word is omitted as non-content.

CiQTEK SEM5000 DVIA-MO3000 (211026R3-1) Set Up Report
DVIA-MO3000 abbreviated setup worksheet (serial 211026R3-1). Target equipment CiQTEK SEM5000; dates of setup 23.12.15 and reporting 24.07.06; measurement date 2023.12.15 (Friday) with operator Byeonghun Cho from DAEIL SYSTEMS. Place of installation and END USER are shown as a dash on the form; place of measurement is N/A. Overview states the DVIA-MO3000 platform is appropriately installed and functioning as intended. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. The internal-program section title reads “MB1000 internal program performance measurement result”; published figures are three program captures labeled Vertical, Left to Right, and Front to Back.

Custom Equipment STM DVIA-MO1000 (230608R2) Installation Report
DVIA-MO1000 abbreviated setup worksheet (serial 230608R2). Date of setup 24.07.01 and reporting 24.07.06; measurement date 2024.07.01 (Monday) with operator Byeonghun Cho from DAEIL SYSTEMS. Target equipment STM; place of installation, END USER, and place of measurement are dash or N/A on the form. Overview states the DVIA-MO1000 platform is appropriately installed and functioning as intended. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. The internal-program section title reads “MB1000 internal program performance measurement result”; published figures are three program captures labeled Vertical, Left to Right, and Front to Back.

Guoxuan Hi-Tech Thermo Fisher Apreo 2S HiVac DVIA-M1000 (230806R6) Set Up Report
DVIA-M1000 set-up report issued under title line MB1000_230806R6 for Thermo Fisher Apreo 2S HiVac at Guoxuan Hi-Tech (Hefei). Overview matches the issued form. Published plots are three distinct MB1000 internal-program performance screens under Vertical, Left to Right, and Front to Back (DOCX §2a: image1→Vertical, image2→Left to Right, image3→Front to Back). Abbreviated field layout without measurement summary table or Reference appendix in the source.