YIMO N/A N/A N/A DVIA-MB1000 (240102R2) Installation Report
DVIA-MB1000 installation report (serial 240102R2). Published figures: vertical-transmissibility, left-to-right-transmissibility, front-to-back-transmissibility. Reference uses the standard Generic Vibration Criteria markdown table.

YIMO ZEISS FE-SEM Sigma360 DVIA-MB1000 (240119R5) Installation Report — Wuxi Aotewei Technology
DVIA-MB1000 installation report (serial 240119R5) via YIMO for Wuxi Aotewei Technology Co., Ltd., ZEISS Sigma360 FE-SEM in Wuxi, China. Overview reproduces the published form wording. The handout has no separate End User, Vibration specification, or measurement summary table. Equipment condition lines are reproduced verbatim. Tuning request is shown as the embedded UI capture; Data and Image publishes vertical, left-to-right, and front-to-back transmissibility plus an equipment picture. Decorative header raster and the Generic Vibration Criteria figure are omitted from public assets; Reference is the standard markdown table only.

Novelis Aluminum Zhenjiang ZEISS Sigma360 SEM DVIA-M1000 (240205R4) Installation Report
DVIA-M1000 installation report (serial 240205R4) for Novelis Aluminum in Zhenjiang. Overview states the platform is appropriately installed and functioning as intended. End User N/A on the form. ZEISS Sigma360 SEM; equipment condition The equipment is installed. Tuning Request UI capture and vertical / left-to-right / front-to-back transmissibility plots; Reference uses the standard VC criterion table.

Youyan Yijin New Materials Thermo fisher Helios G5 FIB-SEM DVIA-M1000 (240205R5) Installation Report
DVIA-M1000 installation report — Thermo fisher FIB-SEM Helios G5 (serial 240205R5) for Youyan Yijin New Materials Co., Ltd. Overview states the platform is appropriately installed and functioning as intended. Tuning May 15, 2024; report written date on the form is 24.07.06. Location 德州. The published form has no End User row and no vibration specification section. Equipment condition The equipment is installed. Tuning Request N/A (no tuning-request figure in this handout). Published plots are vertical, left-to-right, and front-to-back transmissibility from the measurement UI program, plus an on-site equipment photo; Reference uses the standard VC criterion markdown table only.

Korea University R&D Center RAITH PIONEER Two DVIA-MB1000 Installation Report
Korea University R&D Center RAITH PIONEER Two DVIA-MB1000 Installation

FEI FE-SEM NOVA NANOSEM 450 DVIA-M1000 (160808R2-2) Installation Report — 2024-07-05
Compact DVIA-M1000 setup worksheet (serial 160808R2-2) for FEI FE-SEM NOVA NANOSEM 450: form table (END USER and installation site N/A in source), overview sentence, then M1000 internal-program performance plots labeled Vertical, Left to Right, and Front to Back. Reference uses the standard Generic Vibration Criteria markdown table.