FATRI-UTC ZEISS Gemini DVIA-MB1000 (MB1000 P55) Installation report — 2018.03.08
DVIA-MB1000 worksheet referenced as MB1000 P55 for FATRI-UTC with target equipment ZEISS-Gemimi at the 1st-floor analysis lab (cleanroom). Business trip 2018-03-05~2018-03-07; report written 2018-03-08; measurement on 2018-03-06 by Daeil Systems. The public page includes the VC-Class summary chart under the measurement summary, MB1000 internal-program screenshots for Z, X, and Y axes, and octave-band plots (floor vs isolator top) for each axis. A decorative bitmap preceding the FATRI-UTC title block (DOCX image1) is not republished.

Tier-1 Semiconductor Bruker VERTEX 80 DVIA-U1000 (UO1000_P5) Installation Report — Seoul
DVIA-U1000 compact worksheet UO1000_P5 for Bruker VERTEX 80 at Tier-1 Semiconductor (Seoul Samsung Hospital B4 animal laboratory). Business trip and report written 18.02.06; operator Hyungmoon Choi. VC-Class summary table (building floor vs isolator top plate) and follow-up notes per the form; MB1000 internal-program and octave-band (floor vs isolator top) Z/X/Y screenshots per §2a embed mapping. Decorative header bitmap (image1) omitted.

YIMO Fudan Universityersity site — MC3000 / MC1000 / MB1000 vibration setup report (2018-01-30)
Full YIMO multi-system handout (2018-01-30): five isolator sets at Fudan Universityersity B1 analytical lab — MC3000(P6)/TEM, MC1000(P65)/Bruker Ascend400 NMR, MB1000(P57)/Hitachi HT7700, MB1000(P59)/Bruker APEX DUO X-ray, MB1000(P61)/FEI Nova NanoSEM450. Each block includes VC-Class summary tables, UI program Z/X/Y plots, and vibration-environment Z/X/Y plots where present in the source (29 figures; decorative cover raster omitted). Reference uses the shared Generic Vibration Criteria markdown table.

Fudan University Bruker Ascend400 (NMR) DVIA-MC1000 (MC1000 P65 · 171114R5) — YIMO setup report — 2018-01
CHINA YIMO_TECH multi-system setup and vibration measurement worksheet (2018-01-25–26) at Fudan University B1 analytical lab. This public case publishes only the MC1000(P65) / Bruker Ascend400 (NMR) block: VC-Class summary as printed, the two Korean summary bullets verbatim (English page translates them), one installation photograph, UI program performance captures for Z/X/Y, and vibration-environment measurement captures for Z/X/Y. Other systems in the same source file are not shown here.

DVIA MC 3000 FEI TEM TECHNAI G2 F20
Active vibration isolation system DVIA MC 3000 FEI TEM TECHNAI G2 F20 INSTALLATION REPORT

DVIA MC1000 BRUKER NMR Ascend 400
Active vibration isolation system DVIA MC1000 BRUKER NMR Ascend 400 INSTALLATION REPORT