Skip to main content

Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1246 case studies
Guangzhou Monalisa Tile R&D ZEISS evo18 DVIA-MB1000 (MB1000 P51) business-trip report — 2018.04.12

DVIA-MB1000 MB1000 P51 worksheet from a China business-trip report for ZEISS evo18 at Monalisa Tile R&D (Guangzhou, 1st floor). Trip 2018-04-08~09, measurement 2018-04-09, report dated 2018-04-12 by Choi Seong-won (Daeil Systems). The public page reproduces the VC-Class summary grid (Floor and Above Active rows), the Korean performance notes, the worksheet block under (MB1000_P51 셋업) (DOCX image2), MB1000 internal-program Z/X/Y captures (image3–5), and octave-band Z/X/Y plots (image6–8). Decorative title raster (image1, §2a) is omitted.

MONALISA TILES ZEISS evo18 DVIA-MB1000 (MB1000) Installation worksheet — 2018.04.12

DVIA-M type (MB1000) installation test worksheet for MONALISA TILES with target equipment ZEISS-evo18 at the research center 1th floor. Business trip 2018-04-08~2018-04-09; measurement 2018-04-09 (Daeil System, Manager Sung Won Choi); Date Created 2018-04-12. The public page includes the on-site installation photograph, the VC-class summary table as issued, MB1000 internal-program Z, X, and Y transmissibility and coherence plots, and octave-band floor versus above-active plots. The handout does not include a Reference or Generic Vibration Criteria section, and none was added.

ZEISS SIGMA 300VP DVIA-MB1000 (MB1000 P28) 2nd Inspection Report — 2018.04.10

DVIA-MB1000 MB1000 program P28 handout for a ZEISS SIGMA 300VP at DONGJI UNIV (1F): setup and reporting metadata, VC-Class summary (Floor E/E/E; Above Active G/G/G), Good omnidirectional performance and attached VC-Class graph statement, MB1000 internal-program Z/X/Y plots, and octave-band (BASE Floor vs TOP Above Active) Z/X/Y plots. The centered worksheet graphic under the MB1000_P28 setup title is not republished.

FEI Nova NanoSEM450 DVIA-MB1000 (MB1000 P61) Performance Report — 2018.04.10

DVIA-MB1000 MB1000 program P61 handout for an FEI Nova NanoSEM450 at Fudan UNIV (Basement 1F) with END USER DONGJI UNIV: setup and reporting metadata, VC-Class summary (Floor E/E/E; Above Active E/G/F), Good omnidirectional performance and attached VC-Class graph statement, MB1000 internal-program Z/X/Y plots, and octave-band (BASE Floor vs TOP Above Active) Z/X/Y plots. The centered worksheet graphic under the MB1000_P61 setup title is not republished.

Fudan University OXFORD AS400 NMR DVIA-MB1000 (MB1000 program P75) Performance Report — 2018.04.10

MB1000 program P75 performance handout for an OXFORD AS400 NMR at Fudan University (basement 1F). Site and MC1000 P75 setup photograph, VC-class summary table (floor vs above active), MB1000 internal-program measurement plots for Z/X/Y, and octave-band results (BASE: floor, TOP: above active). Field engineer Choi, HyoungMun (DAEIL SYSTEMS); measurement 2018-03-30; report created 2018-04-10.

Fudan University MC1000 (P76) Bruker UltraShield 500 NMR performance report — 2018-04-10

MC1000 (P76) active-mount vibration check for a Bruker UltraShield 500 NMR at Fudan University basement B1: trip 2018-03-30, report 2018-04-10, engineer Choi Hyoung Mun (DAEIL SYSTEMS). Publishes VC-class summary, MB1000 internal-program Z/X/Y plots, and octave-band floor vs above-active Z/X/Y plots from the source handout. Generic Vibration Criteria are given as the site markdown table only.