Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

ZEISS FE SEM DVIA-MB1000 P178 Internal Program Performance — Tier-1 Semiconductor — 2020.07.17
MB1000 internal-program handout for P178 with ZEISS FE SEM at a Tier-1 Semiconductor fab (Icheon): setup and report dated 2020-07-16/17, measurement 2020-07-17 by Manager Choi, Hyoung Mun (DAEIL SYSTEMS). Publishes DAQ setup photos, VC-Class summary table, Z/X/Y internal-program screenshots, and octave-band plots (BASE: Floor, TOP: Above Active). Decorative title-block raster (DOCX image1) and Generic Vibration Criteria table/chart rasters (image5–6) are omitted in favor of the standard markdown VC reference table.

FEI NOVA450 DVIA-MB1000 (MB1000 P8) installation worksheet — Seoul Hanyang University — 2020-07-14
MB1000 program P8 handout after active mounting at Hanyang University Fusion Technology Center (2nd floor) for FEI NOVA450: site photograph, LAN-XI and PCB reference images, LabShop screenshot, PASS/F-style VC-Class summary across floor versus above active vibration isolation, MB1000 internal-program Z/X/Y plots, octave-band spectra (Floor vs Above Active). Generic VC table and VC curve snapshots from Word are folded into the markdown Reference.

Southern University of Science & Technology Thermo Scientific Aquilos DVIA-MB1000 (191025R5 · MB1000 P152) Remote tuning — Installation site · internal program plots — 2020.07.14
DVIA-MB1000 worksheet serialized as MB1000_191025R5 (internal program worksheet P152) for Thermo Scientific Aquilos at Southern University of science and technology in Shenzhen, tuning and reporting dated 2020.07.14 via YIMO-handled remote worksheet. The authoring template merges overview lines and VC-Class wording into one worksheet cell—the web copy keeps only verbatim lines reproduced from the plaintext extract under Measurement summary. Aquilos on DVIA-M1000 is shown in the laboratory site photo ahead of MB1000 internal-program Z, X, and Y transmissibility-and-coherence plots in worksheet order; END USER reads “Southern University”.

Southern University of Science and Technology Thermo Scientific Helios G4 UC DVIA-MB1000 (191121R3 · P150) Remote measurement — Internal program plots — 2020.07.14
YIMO-format remote handout (source “MB1000_P150 yimo(원격) 20.07.14.docx”) for DVIA-MB1000 serial 191121R3 with Thermo Scientific Helios G4 UC at Southern University of science and technology in Shenzhen. The VC-Class summary grid is reproduced with empty Floor / Above Active cells as in the Word form; “Good omnidirectional performance.” follows the issued text. The raster directly under the centered “MB1000_191121R3 Set up” heading is ornamental and is not republished; MB1000 internal-program Z, X, and Y screenshots follow Word §2a order (image2–image4).

FEI DVIA-MB1000 Program (P140 / 190916R2) Installation Report — 2020.07.07
MB1000 program internal handout for FEI target equipment (document title line MB1000_P140 190916R2 Set up): qualitative overview text, VC-Class summary table with empty nominal cells where the worksheet leaves them blank, and MB1000 internal-program capture panels for Z, X, and Y. The raster embedded immediately beneath the centered Word title line is omitted from the published page as header decoration.

FEI DVIA-MB1000 Program (P167 / 200522R1-2) Installation Report — 2020.07.01
MB1000 program internal handout for FEI target equipment (document title MB1000_200522R1-2): overview and measurement summary table with qualitative note, plus MB1000 internal-program Z/X/Y performance plots. The centered graphic inserted immediately under the Word title line is omitted as cover decoration; this release has no VC comparison figures or Reference section in the source file.