Novartis Thermo Fisher Scientific Glacios DVIA-MB3000 (201012R5) Installation Report — 2021.04.21
DVIA-MB3000 (serial 201012R5, internal P15) remote VEC worksheet for Thermo Fisher Scientific Glacios at Novartis (MA): transmissibility and VC-class summary tables, MB1000 internal program axis plots, and VEC measurement graphics. Setup and measurement 2021-04-21; reporting 2021-04-22; operator Doohyun Kim (DAEIL SYSTEMS, research engineer). Historical business-trip window 2017-12-27~2017-12-29 per report header.

Thermo Fisher Scientific NXQ8000 Mask Aligner DVIA-MB1000 remote VEC (210302R3) Installation Report — 2021.04.20
Remote VEC worksheet for DVIA-MB1000 (serial 210302R3, internal P224) under THERMO FISCHER NXQ8000 Mask Aligner at Thermo Fisher Scientific, CA (B1). Operator Doohyun Kim; measurement 2021-04-08; setup and reporting dates as stated on the form; business trip window per header. Publishes equipment photograph, MB1000 internal program axis plots, and VEC measurement axis plots extracted from Word. The source handout has no Reference / Generic Vibration Criteria section — none was added.
LB Semicon TESCAN MIRA DVIA-MB1000 (MB1000 P220) Installation Report — 2021.04.16
MB1000 internal-program worksheet (P220) for TESCAN MIRA at LB Semicon (2F annex laboratory): VC-Class summary table, B&K measurement-chain figures, MB1000 internal-program Z/X/Y transmissibility plots, and floor versus isolated-top VC comparison spectra by axis. Generic Vibration Criteria table and standalone VC curve chart embedded in Word are omitted on the public page in favor of the standard markdown Reference table.

Shagang Group ZEISS Crossbeam 550 DVIA-MB1000 (201028R1 · P202, YIMO remote tuning) — 2021.04.12
DVIA-MB1000 serial 201028R1 (project P202) for ZEISS Crossbeam 550 reported by YIMO/channel partner Shagang Group (Zhangjiagang installation line). Remote performance worksheet: dates 2021-04-12 (setup and measurement) / 2021-04-13 (reporting), operator Doohyun Kim (DAEIL SYSTEMS research engineer). Publishes the setup photograph from under the worksheet title, transmissibility summary at 2 / 5 / 10 Hz, and MB1000 internal-program captures under Z / X / Y axis captions as in Word.

TPK Holding Co., Ltd Thermo Fisher Helios G5 DVIA-MB1000 (201214R4 · P216) Remote measurement — Internal program plots — 2021.04.09
DVIA-MB1000 serial 201214R4 (project P216) for Thermo Fisher Helios G5 reported by YIMO/channel partner; installation-site table cites Xiamen TPK Holding 4F with measurement dated 2021.04.08 also at Xiamen. Figures follow Z axis, X axis, and Y axis as in Word; the photo embedded directly under (P216) Set up is ornamental and is not republished.
Tier-1 Semiconductor ZEISS Xradia 620 Versa DVIA-MB3000 (201201R2 P18) Installation Worksheet — 2021.03.31
DVIA-MB3000 (serial 201201R2, P18) on-site worksheet dated 2021.03.31 at Tier-1 Semiconductor with ZEISS Xradia 620 Versa: B&K PULSE measurement setup, VC-class summary, internal program plots (Z/X/Y), and vibration criterion curves. B&K PULSE 14 & LAN-XI Type 3056; PCB 393B05. Report written 2021.04.01; business trip record 2017.12.27–2017.12.29.