Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

Oi Solution Co., Ltd. JEOL JSM-7610F PLUS DVIA-MB1000 (MB1000_P222) Installation Report — March 2021
Active-mount vibration survey for JEOL JSM-7610F PLUS at Korea Photonics Technology Institute — B&K PULSE setup, VC summary, MB1000 internal program plots, and vibration criterion overlays by axis.

ZEISS-Gemini DVIA-MB1000 MB1000 P197 (200928R2) Internal Program Performance — 2021.03.15
DVIA-MB1000 program MB1000 P197 internal handout dated 2020-09-28 (revision R2 on cover): target equipment ZEISS-Gemini, onsite summary transmissibility table, MB1000 internal-program performance plots under Z, X, and Y axis headings from the Word source (cover title decorative graphic omitted from uploads). Setup fields left blank at source are published as N/A.

CNITECH Qianwan Institute Thermo Fisher Scientific Helios 5 CX DVIA-MB1000 (191219R3-2) — MB1000 P169 worksheet — 2021.03.11
Ingested from DOCX “MB1000 P169 191219R3-2 21.03.10.docx”. MB1000 P169 worksheet for Thermo Fisher Scientific Helios 5 CX at CNITECH / Qianwan Institute: operator Choi, HyoungMun; setup and measurement 2021-03-10; reporting 2021-03-11. Includes the site summary table, transmissibility summary at 2 Hz / 5 Hz / 10 Hz, the equipment photo used after the report title line, and Z / X / Y MB1000 internal-program plots. No “Reference / Generic Vibration Criteria” section exists in this Word file — the public case does not add one.

Echeng Iron & Steel (鄂城钢铁) Zeiss Evo 18 DVIA-MB1000 (200630R2 · P198) Remote measurement — Internal program plots — 2021.03.09
DVIA-MB1000 serial 200630R2 (project P198) for Zeiss Evo 18 via YIMO channel partner; END USER 鄂城钢铁 (Echeng Iron & Steel) and installation site summary list Hubei. Internal-program plots follow **Z axis**, **X axis**, and **Y axis** headings as in the Word document. The title-line decorative graphic embedded on the centered setup heading paragraph is not republished.

Tsinghua University Thermo Fisher Scientific Aquilos DVIA-MB1000 (201229R2 · P203) Remote tuning worksheet — Internal program plots — 2021.03.02
DVIA-MB1000 serial 201229R2 (project P203) for Thermofisher Aquilos at Tsinghua University, reported via YIMO/channel partner channel. Setup and reporting dates 2021-03-02; measurement at Tsinghua University per the form. Publishes transmissibility summary and MB1000 internal-program Z/X/Y screenshots. Decorative image under the MB1000 setup title line is not republished. The source handout has no Reference / Generic Vibration Criteria section — none was added.

Nanfu Battery Hitachi SU1000 FlexSEM 1000II DVIA-UB350 (201021R4 P1) YIMO Remote-Tuning Report
YIMO channel remote-tuning handout (21.02.22) for DVIA-UB350s set 201021R4(P1) under Hitachi SU1000 FlexSEM 1000II at Nanping city, 4F end user 南孚电池. Operator Munho Noh; business trip 17.12.27–17.12.29. Transmissibility at 2 Hz and 10 Hz is tabulated; three MB1000 UI–style internal-program displays are published for Z, X, and Y axes. The JPEG under the title line before the summary tables is omitted as a title-block graphic.