Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1246 case studies
Shihu Technology Nanjing SUSS MA/BA Gen4 Pro DVIA-MB1000 — Remote setup — 2021.06.18

DVIA-MB1000 setup MB1000_210316R5(P229) for Shihu Technology (Nanjing), target equipment BOND ALINGER / SUSS MA/BA Gen4 Pro — onsite vibration check after active mounting, transmissibility summary table, and internal-program Z/X/Y plots. Decorative header graphic behind the setup title is not republished.

KBSI (Ochang) MC3000 P20 / 210422R1 vibration worksheet — 2021.06.18

MC3000 serial 210422R1 (program P20) worksheet at Korea Basic Science Institute (Ochang): in-house developed equipment, measurement on 2021-06-17, report dated 2021-06-18. PULSE 14 setup, VC-Class summary table (Floor vs Above Active), wide-format measurement plots, and Z/X/Y vibration criterion curves.

Tier-1 Semiconductor ZEISS Crossbeam 550 DVIA-MB1000 (210607R3 P231) Installation Worksheet — 2021.06.16

DVIA-MB1000 (serial 210607R3, program P231) on-site worksheet dated 2021.06.16 at Tier-1 Semiconductor (Icheon, P&T Building 1) with ZEISS Crossbeam 550: B&K PULSE 14 & LAN-XI Type 3056 setup, VC-class summary table, three wide measurement plots under Measurement conditions and results, two measurement-summary visuals after the summary line, and Z/X/Y vibration criterion curve captures. Report written 2021.06.17; business trip record 2017.12.27–2017.12.29.

Inner Mongolia University Hitachi S4800 DVIA-MB1000 remote VEC (201216R1-1 / P209) — 2021.06.10

Remote VEC worksheet for DVIA-MB1000 (serial 201216R1-1, internal program P209) with Hitachi S4800 at Inner Mongolia University (NeiMengGu). Operator Munho Noh (Daeil Systems); setup and reporting dates match the Word worksheet. Transmissibility summary and MB1000 internal-program Z/X/Y plots are published from the DOCX embeds; the worksheet does not include a VC Class table or a Reference section, so neither was added.

YIMO remote tuning — Inner Mongolia Univ. Hitachi SU8100 DVIA-MB1000 (201216R1-2 · P211) — 2021.06.10

YIMO-format remote-tuning worksheet for DVIA-MB1000 serial 201216R1-2 (platform P211) at Inner Mongolia University with Hitachi SU8100 listed as target equipment; operator Munho Noh (Daeil Systems, research engineer). Setup, measurement, and reporting on 2021.06.10. Figures are the MB1000-internal-program Z / X / Y performance screens plus the Transmissibility table; Word title-bar raster beneath the centred heading line is intentionally omitted.

Inner Mongolia University Hitachi HT7800 DVIA-MB1000 (201216R1-3 · P217) Remote measurement — Internal program plots — 2021.06.10

YIMO-format remote-tuning handout for DVIA-MB1000 serial 201216R1-3 (project P217) at Inner Mongolia University with Hitachi HT7800 as the stated target equipment. Operator Munho Noh (Daeil System, research engineer); setup, measurement, and reporting on 2021.06.10; place of measurement NeiMengGu per the form. Published figures are the MB1000 internal-program Z/X/Y performance screens only; the Word header raster under the title line is omitted from the public gallery. The source handout has no Reference / Generic Vibration Criteria section.