Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

YIMO Thermo Fisher Scientific APREO 2S DVIA-MB1000 (210701R6-1 P241) Installation Report — 2021.08.24
YIMO-format DVIA-MB1000 worksheet (serial 210701R6-1, platform P241) for Thermo Fisher Scientific APREO 2S. Operator Kim, Doohyun (Daeil System, research engineer); setup and reporting on 2021.08.24; measurement date 21.08.24 (Tuesday). END USER and installation site fields are blank on the form (published as N/A). Published plots are the MB1000 internal-program Z, X, and Y axis performance screens only; the Word title-line decorative raster (image1) is omitted from public assets. The source has no Reference appendix.

YIMO remote tuning — Mongolia University FEI TF20 DVIA-MB3000 (201216R1-4 P16) — 2021.08.23
YIMO-format remote tuning worksheet for DVIA-MB3000 serial 201216R1-4 (platform label P16) with installation place Huhehaote, Mongolia University, and FEI TF20 as the stated target equipment. Operator Yu, HoSang (Daeil System, research engineer); setup 2021.08.20 and measurement 2021.08.23; reporting 2021.08.23. Published figures are MB3000 internal-program Z/X/Y performance screens only; the Word header raster directly under the title line is omitted from the public gallery. The supplied form has no Reference / VC criteria appendix.

YIMO THERMO APREO 2S DVIA-MB1000 (P237) Internal program performance — 2021.08.18
DVIA-MB1000 worksheet P237 for THERMO APREO 2S (measurement dated 2021.08.18; operator Choi, HyoungMun, Daeil System). Setup and overview text follow the DOCX summary tables as published; MB1000 internal-program plots align with Z axis, X axis, and Y axis headings. The decorative raster on the centred title line is not republished.

无锡英诺赛思 ZEISS Sigma 300 DVIA-MB1000 (P235) Internal Program Performance — 2021.08.10
DVIA-MB1000 program MB1000 P235 — Wuxi Yingnuo Technology, target equipment ZEISS Sigma 300. Internal-program plots follow Z axis, X axis, and Y axis headings as in the source. The title-line graphic between the report heading and the setup tables is not republished.

Thermo Fisher Apreo DVIA-M1000 (210420R2) Installation Report — MacDermid Enthone — 2021.08.04
DVIA-M1000 serial 210420R2 for MacDermid Enthone, target equipment Thermo Fisher Scientific FIB-SEM Apreo. The published excerpts are the Vertical, Left-to-Right, and Front-to-Back Transmissibility plots from Data and Image. The ISO/VC reference material in the handout appears as an on-site markdown table instead of a separate figure.

YIMO DVIA-MB1000 (P160) Internal program performance — 2021.08.04
DVIA-MB1000 worksheet P160 for YIMO (measurement reporting dated 2021.08.04; operator Kim, Doohyun, Daeil System). Overview and transmissibility summary follow the DOCX as published; internal-program plots follow Z axis, X axis, and Y axis headings. The decorative raster on the centred title line is not republished.