Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

NSK Guangzhou Zeiss Sigma300 UB1000 P17 Remote Tuning Installation Report (210325R6, 2021-10-13)
UB1000 (S/N 210325R6, P17 remote tuning worksheet) vibration check after active mounting on Zeiss Sigma300 at guangzhou for END USER 恩斯克. Operator Kim, Doohyun; setup and reporting 2021-10-13. Publication includes transmissibility summary at 2 / 3 / 10 Hz (Z/X/Y) and UB1000 internal-program Z/X/Y axis plots; decorative title-block JPEG (image1) omitted.

Sun Yat-sen University Guangzhou MB3000 P246 DVIA-MB3000 (210701R6-5) internal program — 2021.10.13
DVIA-MB3000 MB3000 P246 worksheet (serial 210701R6-5) after active mounting at Sun Yat-sen University, Guangzhou: operator Kim, Doohyun (DAEIL SYSTEMS research engineer), setup and reporting 21.10.13, business trip record 17.12.27~17.12.29 per the form. Publishes omnidirectional transmissibility summary at 2–10 Hz and three internal-program screenshots (Z, X, and Y axis). The decorative title-line JPEG paired with the *MB3000 P246(210701R6-5)* heading in Word is omitted on the public page. No Reference section appears in the source.

Xiamen Haichen Zeiss Sigma300 DVIA-MB1000 (P239 · 210820R1) Installation Report — 2021.10.12
DVIA-MB1000 (P239 / internal ref. 210820R1) for Zeiss Sigma300 at Xiamen Haichen — setup and reporting on 2021.10.12, transmissibility summary at 2 / 5 / 10 Hz, and internal-program Z / X / Y plots plus an on-site equipment photograph as in the source.

Huawei TESCAN Solaris GMH DVIA-M1000 Installation Report (YIMO, MB1000 P249, 210517R4) — 2021.09.29
MB1000 internal-program worksheet (P249, report 210517R4) for TESCAN Solaris GMH with END USER Huawei — transmissibility summary at 2/5/10 Hz and Z/X/Y internal-program plots. Place of installation and place of measurement are N/A on the form.

YIMO STM OEM DVIA-MO1000 (P247) Second Setup Installation Report — September 13, 2021
MO1000 internal-program handout for DVIA-MO1000 serial P247 via YIMO (second setup). Measurement on 2021-09-10 with summary transmissibility table and Z–X–Y internal program screenshots. Cover-only header raster is omitted from publication.

YIMO Thermo Fisher Apreo 2S DVIA-MB1000 (210701R6-2 P242) Installation Report
YIMO-format internal-program handout for DVIA-MB1000 serial 210701R6-2 (platform P242) with Thermo Fisher Scientific Apreo 2S as the target equipment. Operator KIM, DOOHYUN (Daeil System, research engineer); setup and measurement on 2021.08.20; reporting on 2021.09.06. Published figures are the MB1000 internal-program Z/X/Y performance screens only; the Word title-line header raster is omitted from the public gallery. Place of installation and END USER are blank on the form (N/A). The source handout has no Reference / VC criteria appendix.