Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

YIMO Zeiss EVO10 DVIA-MB1000 (210903R3) Internal Program Performance — 2021.11.11
DVIA-MB1000 serial 210903R3 — YIMO job reference P252, target equipment Zeiss-EVO10, onsite work 2021-11-10 with report date 2021-11-11. Internal-program plots follow Z axis, X axis, and Y axis headings as in the source. The title-block raster mapped to "MB1000 P252 210903R3" in Word is not republished.

CETC 13 Institute Thermofisher Scios2 DVIA-M1000 Installation Worksheet (210322R1) — 2021-11-08
MB1000-format worksheet headed MB1000 P255 210322R1 for Thermofisher Scios2 at CETC 13 institute (END USER Shijiazhuang). Setup 2021-11-05, reporting 2021-11-08; operator Choi HyoungMun (Daeil Systems). Publishes the worksheet capture under the header row, text transmissibility summary at 2 / 5 / 10 Hz, and MB1000 internal-program Z / X / Y screenshots.

ZOLIX DVIA-M1000 MB1000 (210610R1) Installation Report — 2021.11.08
DVIA-M1000 MB1000 worksheet (serial 210610R1, project line P254). After active mounting, floor transmissibility was summarised at 2, 5, and 10 Hz; internal-program Z / X / Y plots are published from the embedded captures. Target equipment, installation site, and end-user cells are blank on the form and are shown as N/A. Title-block photograph included under the worksheet heading.

CETC 13 Institute Thermofisher Scios2 DVIA-M1000 Worksheet (MB1000 P255 · 210322R1) — 2021-11-08
MB1000-format worksheet headed MB1000 P255 210322R1 for Thermofisher Scios2 at CETC 13 institute (END USER Shijiazhuang). Setup 2021-11-05, reporting 2021-11-08; operator Choi HyoungMun (Daeil Systems). Publishes the worksheet capture under the header row, text transmissibility summary at 2 / 5 / 10 Hz, and MB1000 internal-program Z / X / Y screenshots.

ZOLIX DVIA-M1000 MB1000 P254 (210610R1) Installation Report — 2021.11.08
DVIA-M1000 MB1000 worksheet (serial 210610R1, project line P254). After active mounting, floor transmissibility was summarised at 2, 5, and 10 Hz; internal-program Z / X / Y plots are published from the embedded captures. Target equipment, installation site, and end-user cells are blank on the form and are shown as N/A. Title-block photograph included under the worksheet heading.

BOE ZEISS CROSSBEAN350 DVIA-MB1000 (210705R1) Internal Program Performance — 2021.11.05
DVIA-MB1000 serial 210705R1 internal-program worksheet for BOE with target equipment ZEISS CROSSBEAN350. Setup 2021-11-04, reporting 2021-11-05; operator Choi HyoungMun (DAEIL SYSTEMS research engineer). Includes transmissibility summary table at 2 / 5 / 10 Hz and Z / X / Y internal-program plots under the axis captions from the source.