Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

ZEISS Sigma 300 DVIA-MB1000 (P227 / 210503R7) NEMO worksheet — 2022-01-07
NEMO handout MB1000 P227 NEMO 22.01.07.docx — target ZEISS Sigma 300, reporting 22.01.07 (setup 22.01.04). Transmissibility summary at 2/5/10 Hz and MB1000 internal-program Z/X/Y screenshots follow DOCX §2a mapping (rId9–11 → image2–4); the centred title-line ornament (rId8 / image1) is not republished.

Baosteel ZEISS Sigma 300 DVIA-MB1000 (P205) Internal Program Performance — 2021.12.29
DVIA-MB1000 program MB1000 P205 (source MB1000 P205 NEMO 21.12.29.docx) for Baosteel with target equipment ZEISS Sigma 300 at R&D Center 3Floor. Publishes setup field table, Overview, measurement metadata, transmissibility summary at 2/5/10 Hz (Z/X/Y), and MB1000 internal-program plots under Z axis, X axis, and Y axis in DOCX embed order (image2–4). The centered title-line graphic before the setup fields (word/media image1) is omitted from the public page.

YIMO Thermofisher Apreo DVIA-MB1000 (211020R5) Installation Report — 2021.12.23
DVIA-MB1000 field worksheet (serial 211020R5, MB1000 P269 line) prepared by YIMO for Thermofisher Apreo. Dates on the form: setup 21.12.22, reporting 21.12.23, business-trip line 17.12.27~17.12.29. The Overview block and transmissibility summary match the Word table layout; internal-program section title reads “MB1000 internal program performance measurement result” with Z / X / Y axis program screenshots. The title-line setup bitmap under “MB1000 P269 211020R5” (Word image1) is omitted from public copy per installation-report decoration rules.

YIMO ZEISS Sigma 300 DVIA-M1000 MB1000 Internal Program Worksheet (2021-12-17)
MB1000 P272 handout for DVIA-M1000 serial 211122R5 with ZEISS Sigma 300: setup capture under the title row, summary transmissibility table, and Signal-program internal performance plots for Z, X, and Y. Form lists YIMO in the source filename; END USER and installation location cells are blank on the sheet.
Carl Zeiss ZEISS-Xradia 620 Versa DVIA-MB3000 (MB3000_P24) Worksheet — Tier-1 Semiconductor — 2021.12.17
DVIA-MB3000 worksheet MB3000_P24 for a Carl Zeiss ZEISS-Xradia 620 Versa installation at a Tier-1 Semiconductor facility (SK 이노베이션, Building 3-2, B1): overview, DAQ settings, VC-class summary versus floor and active platform, field notes, MB3000 internal-program performance graphics (Z/X/Y), and vibration criterion curve captures. Setup 2021.12.16; reporting 2021.12.17; operator Choi, HyoungMun (DAEIL SYSTEMS research engineer).

YIMO Hitachi SU8100 MB1000 P261 (211013R1) internal program handout — 2021.12.13
YIMO-format active-mounting worksheet for platform MB1000 P261 serial 211013R1 with HITACH SU8100 as the stated target equipment. Operator Choi HyoungMun (Daeil System, research engineer); setup 2021.11.30; reporting 2021.12.13; business trip 17.12.27~17.12.29. Published figures are the MB1000 internal-program Z/X/Y performance screens only; the Word header raster under the title line is omitted from the public gallery. The source handout has no Reference / VC criteria appendix.