Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1246 case studies
Guangdong Xiandao ZEISS Sigma 300 DVIA-M1000 Installation Report (2022-04-06)

Prepared for Guangdong Xiandao — DVIA-M1000 (SN 220107R1) with ZEISS Sigma300 in Qingyuan, China. Measurement transmissibility plots (Z / X / Y) and installation photo.

SLAC Thermo Scientific Aquilos II DVIA-MB1000 (211012R6-2) Installation Report — 2022.03.10

DVIA-MB1000 VEC-style worksheet (serial 211012R6-2) at SLAC National Accelerator Laboratory Cryo EM Lab under Thermo Scientific Aquilos II (Menlo Park, CA). Work completed March 10, 2022; Corey Hencksel prepared-for contact; site photograph and Z/X/Y floor, platform-on, and transmissibility plots uploaded from the Word source (decorative web-address header raster omitted).

Xiamen Farad Electronics Thermo Fisher Apreo 2S DVIA-M1000 MB1000 Worksheet (211206R2) — 2022-01-24

MB1000 internal-program handout (platform serial 211206R2, worksheet title MB1000 P275) for Thermo Fisher Apreo 2S at CABOT, Xiamen Farad Electronics. Operator Yu Hosang (Daeil Systems); setup 2022-01-19; reporting 2022-01-24. Posts transmissibility summary table, field setup image, and Z/X/Y MB1000 program plots.

YIMO UB1000 P24 (200828R4) ZEISS Sigma 300 remote tuning measurement report

UB1000 vibration isolation serial 200828R4 setup and measurement handout (YIMO path) for target equipment ZEISS Sigma 300 at a Tier-1 Semiconductor account. Setup and reporting dated 22.01.10 with operator CHOI, HYOUNGMUN; business-trip reference 17.12.27–17.12.29; overview measurement 22.01.10 (Mon). Publication includes the UB1000 internal-program setup screen plus distinct Z / X / Y performance captures, and transmissibility summary at 5 Hz and 10 Hz. Fields left blank on the handout appear as N/A. Reference publishes the Generic Vibration Criteria markdown table only (no supplementary diagram).

YIMO UB1000 P26 (210720R4) ZEISS Sigma 300 remote tuning measurement report

UB1000 vibration isolation serial 210720R4 setup report under the target ZEISS Sigma 300 microscope (YIMO path). Setup and measurement documentation dated January 2022: transmissibility summary at 5 Hz and 10 Hz for vertical, lateral, and cross-lateral axes, plus UB1000 internal program performance captures for Z, X, and Y. Fields left blank on the handout appear as N/A. Reference publishes the Generic Vibration Criteria markdown table only (no supplementary diagram).

ZEISS Sigma 300 DVIA-MB1000 (210503R7) YIMO internal program — 2022-01-07

YIMO-format MB1000 P227 handout — SN 210503R7, target ZEISS Sigma 300. Transmissibility summary at 2/5/10 Hz plus MB1000 internal-program Z/X/Y plots; title-block ornament raster from the Word cover is not republished.