Tier-1 Display Manufacturer Paju M2 SNU CTQ Equipment DVIA-UB350 (220211R02) Installation Report

DVIA-UB350(1260×800, serial 220211R02) installation report prepared for SNU Precision, with SNU CTQ equipment at Tier-1 Display Manufacturer (Paju) M2; tuning 2022-05-12 and report written 2022-05-16 by DAEIL SYSTEMS. Equipment Turn on state: vertical / left–right / front–back VC curves and transmissibility plus summary VC-class table (Floor vs Active). Six measurement plots published; decorative header PNG and Reference VC diagram omitted in favor of markdown criteria table.

DVIA-UB700 Required Tools (Field Handout)
Installation Report
DVIA-P Series
04-29-2022

DVIA-UB700 Required Tools (Field Handout)

Summary of the tools and work sequence for unpacking and initial mechanical setup of the DVIA-UB700, with reference photos from the handout. Customer-specific installation data and measurement plots are not part of this publication.

Amazon Web Services Elionix EBL DVIA-M3000 (210915R2) Installation Report — 2022.04.22

DVIA-M3000 (serial 210915R2) installation report dated 22 April 2022 for Elionix EBL at Amazon Web Services (form "Prepared for: AWS"). VC and transmissibility curves for vertical, left-to-right, and front-to-back axes on floor and active isolator, vibration results summary table, and Generic Vibration Criteria as a markdown Reference table. Decorative header bitmap and the standalone Reference criteria figure from the handout were omitted in favor of the site table.

Carl Zeiss Magok LG Science Park ZEISS Versa 620 (X-ray) DVIA-MB3000 (220310R3) Installation Report — 2022.04.22

DVIA-MB3000 (serial 220310R3) worksheet from 22 April 2022 at Carl Zeiss Magok LG Science Park with Versa 620 (X-ray): summary VC table versus floor and active-platform states for Z-, X-, and Y-axis VC curves plus transmissibility plots. Engineers Youngha Lee and Seounghoon Cheon (DAEIL SYSTEMS); report written date 22.04.25. Reference VC criteria are published only as an on-site markdown table (no reference figure asset).

Hanyang University DVIA-MB1000 (141211R5) Installation Report — 2022-04-21

Compact installation report prepared for Hanyang University with DVIA-MB1000 (serial 141211R5) on SEM equipment at the Sungdong, Seoul campus: overview, vibration summary comparing floor versus active VC-class bands across Z / X / Y, VC curves plus transmissibility for each axis at floor versus active measurement points (report header decoration bitmap omitted from publication), and the standard VC reference markdown table.

Korea Institute of Science and Technology (KIST) Microscope DVIA-UD350 (220127R1-1) Installation Report

DVIA-UD350 (SN 220127R1-1) at KIST Building L7 Room 7223, Seongbuk-gu, Seoul, supporting a microscope. Engineers Youngha Lee and Seounghoon Cheon (DAEIL SYSTEMS); tuning and report dated April 21, 2022. Measurement summary table plus Z/X/Y VC curves (Floor and Active), transmissibility plots, and VC criteria as markdown (header decoration image and Word Reference raster omitted).