Wenzhou Hongfeng ZEISS Sigma 300 Haimen DVIA-M1000 Installation Report (220216R1, 2022-05-27)
Wenzhou Hongfeng Electrical Alloy Co., Ltd. abbreviated worksheet — ZEISS Sigma300 at Haimen (serial 220216R1). Setup and reporting dated 22.05.27; measurement on 2022.05.27 (Friday) with operator Seounghoon Cheon from DAEIL SYSTEMS. END USER General Lithium Corporation. Source includes VC-Class summary table, MB1000 internal program plots for Z/X/Y axes, Octave Band Result plots for Z/X/Y axes. Decorative Word header/logo and setup banner embedded before the overview are omitted from public imagery.

Chengdu Jijia Technology TESCAN MIRA DVIA-U1000 (220221R1) Installation Report — Chengdu
DVIA-U1000 compact installation worksheet (serial 220221R1) at Chengdu Jijia Technology with TESCAN MIRA. Setup 22.05.20, reporting 22.05.23, business-trip line 17.12.27~17.12.29; Overview measurement dated 2022.05.20 (Friday). Publication includes setup photograph, U1000 internal-program Transfer rate / TF+Phase captures per axis, and Octave Band Result plots. Decorative header bitmap (image1) omitted.

Chengdu Jijia Technology TESCAN MIRA DVIA-UB700 (220221R1) Installation Report
DVIA-UB700 (serial 220221R1) installation report for Chengdu Jijia Technology (YIMO) with TESCAN MIRA — tuning May 20, 2022, report written May 23, 2022, China: Chengdu Jijia Technology site. Summary table lists floor vs active VC results by axis and band; published plots are Z / X / Y VC curves and dual-band transmissibility (1–10 Hz and 10–80 Hz). Decorative header image and generic vibration-criteria figure are omitted in favor of the site Reference table.

THERMO APREO 2S DVIA-M1000 (210701R6) Re-tuning Report — Opton Guangzhou — 2022.05.18
DVIA-M1000 serial 210701R6 re-tuning handout for THERMO APREO 2S at Opton (GUANGZHOU, 1F). Includes Overview with on-site measurement metadata (2022.05.18), transmissibility summary at 2/5/10 Hz (Z/X/Y), and MB1000 internal program Z/X/Y plots. Decorative header banner and the title-block photo before the setup tables are omitted from the public page.

ZEISS Gemini Crossbeam 350 DVIA-M1000 Installation Report (JuCan Optoelectronics, Suqian, 220106R5, 2022)
Short-field report — DVIA-M1000 220106R5 with ZEISS Gemini Crossbeam 350 at Suqian: VC-Class summary table, set-up photograph, M1000 internal-program captures (Z/X/Y), and octave-band results (Z/X/Y).

Wenzhou Hongfeng ZEISS GeminiSEM 300 Wenzhou DVIA-M1000 Installation Report (210714R2-1, 2022-05-18)
Wenzhou Hongfeng Electrical Alloy Co., Ltd. worksheet — ZEISS GeminiSEM 300 at WENZHOU 3F (serial 210714R2-1). Setup dated 22.05.18, reporting dated 22.05.19; measurement on 2022.05.18 (Wednesday) with operator SungKuk Kim from DAEIL SYSTEMS. END USER Wenzhou Hongfeng Electrical Alloy Co., Ltd. Source includes VC-Class summary table, MB1000 internal program plots for Z/X/Y axes, Octave Band Result plots for Z/X/Y axes. Decorative Word header/logo and setup banner embeddings before measurement content are omitted from public imagery.