Skip to main content

Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1246 case studies
Carl Zeiss Suzhou ZEISS EVO DVIA-M1000 (221130R2) Internal Program Performance — 2023.03.20

DVIA-M1000 serial 221130R2 — worksheet for Carl Zeiss Suzhou Co.,Ltd, target equipment ZEISS EVO, installation and measurement in Suzhou. Overview and in-form metadata match the handout; MB1000 internal program performance screenshots are labeled Z axis, X axis, and Y axis. The header banner image in the Word file was decoration only and is not republished.

FUJIAN ZI JIN TONG BO Axia ChemiSEM LoVac DVIA-U1000 (220718R11) Installation Report

DVIA-U1000 worksheet for FUJIAN ZI JIN TONG BO, Axia ChemiSEM LoVac in FUJIAN, China (serial 220718R11). Setup 23.03.07, report 23.03.10 by Youngha Lee (DAEIL SYSTEMS). Publishes the setup photo under the source title line and Z/X/Y internal-program performance screenshots; omits narrow header bitmap image1.

FUJIAN ZI JIN TONG BO Axia ChemiSEM LoVac DVIA-U1000 (220718R11) Installation Report — Fujian

DVIA-U1000 compact installation worksheet (serial 220718R11) at FUJIAN ZI JIN TONG BO with Axia ChemiSEM LoVac. Setup 23.03.07, reporting 23.03.10, business-trip line 17.12.27~17.12.29; Overview measurement dated 2023.03.07 (Tuesday). Publication includes setup photograph and U1000 internal-program Z / X / Y axis screenshots. Decorative header bitmap (image1) omitted.

Shanghai Shengjian Environmental System Technology Sigma300 DVIA-U1000 (220919R7) Installation Report — Shanghai

DVIA-U1000 compact installation worksheet (report line 220919R7) at Shanghai Shengjian Environmental System Technology Co., Ltd with Zeiss Sigma300. Setup 2023.03.09, reporting 2023.03.10, business-trip line 17.12.27~17.12.29; Overview measurement dated 2023.03.20 (Monday). Publication includes equipment setup photograph and U1000 internal-program Z / X / Y screenshots. Decorative header bitmap (image1.png) omitted.

Yale School of Medicine Zeiss Versa 610 DVIA-MB3000 VEC (230110R4) Installation Report — 2023.03.10

DVIA-MB3000 (serial 230110R4, platform DVIA-MB3000-1370x2180) VEC installation worksheet at Yale School of Medicine Child Study Center (350 George St, New Haven, CT) with Zeiss Versa 610. Includes UI program transmissibility (Z/X/Y), VEC measurement plots (transmissibility, floor VC, active VC per axis), an installed equipment photograph, and Reference as the standard Generic Vibration Criteria markdown table (reference criterion graphic not republished). Engineer Youngha Lee (DAEIL SYSTEMS).

YIMO JEOL JEM 1400 Flash DVIA-M1000 (220126R7-3) Installation Report — Sun Yat-Sen University

DVIA-M1000 installation report (serial 220126R7-3) for JEOL JEM 1400 Flash TEM at Sun Yat-Sen University, Guangdong, China, via YIMO. VC curves (vertical and left-to-right), front-to-back transmissibility, and equipment photo from the published handout. Report written date 23.05.22. Reference uses the standard Generic Vibration Criteria markdown table only.