Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

ECOMI DVIA-M1000 MB1000 internal program performance (230821R3-1, reporting 2024.07)
DVIA-M1000 field note for ECOMI (printed serial 230821R3-1 on the cover line). Setup 2024.03.18, reporting 2024.07.05, measurement dated 2024.02.01. Publishes MB1000 internal-program screenshots labeled Vertical, Left to Right, and Front to Back. Abbreviated Word layout: no site equipment photo block and no Reference appendix in the source.

Xi'an Jiaotong University ZEISS Sigma 300 DVIA-M1000 (231009R3) Installation Report
DVIA-M1000 abbreviated worksheet (serial 231009R3). Setup dated 24.03.22 and reporting dated 24.07.05; measurement date 2024.03.15 (Wednesday) at Xi'an Jiaotong University with operator Chaewon Lee from DAEIL SYSTEMS. END USER matches the institution; target equipment ZEISS Sigma300 and installation site Xi'an as on the form. The Overview block states the standard DVIA-M1000 sentence only. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. The internal-program section title reads “M1000 internal program performance measurement result”; published figures are three plots under Vertical, Left to Right, and Front to Back. Decorative header graphics from the Word file are omitted from public copy.

DVIA-M1000 MB1000 Internal Program (231016R2), Setup 24.05.28
MB1000 worksheet (M1000_ 231016R2 Set-up): setup 24.05.28 / reporting 24.07.05; measurement 2024.05.28. Published Vertical, Left to Right, and Front to Back internal-program screenshots from the issued form. Field entries for target equipment, end user, and site location are N/A or “-” on the source; no cover-only graphics in Storage.

DVIA-M-JT1 (231129R2-1) Installation Report
DVIA-M-JT1 onboard program results (serial 231129R2-1). Operator Chaewon Lee; measurement 2024.04.30 / reporting 24.07.05. Screenshots publish Vertical, Left to Right, and Front to Back per the embedded program labels (section heading text follows the source Word template). Decorative title-block raster under (M-JT1_ … Set-up) omitted.

Northeastern University Shenyang Thermo Fisher Scientific Talos TEM DVIA-M-THT3 (231129R2-2) Installation Report
DVIA-M-THT3 internal-program worksheet (serial 231129R2-2) for a Thermo Fisher Scientific Talos TEM at Northeastern University in Shenyang, China. Setup dated 24.04.30 and reporting dated 24.07.05; measurement date 2024.04.30 (Tuesday) with operator Chaewon Lee from DAEIL SYSTEMS. The source handout has no vibration specification section, equipment condition field, tuning request capture, measurement summary table, or Reference section. Published figures are three M-THT3 internal-program plots labeled Vertical, Left to Right, and Front to Back; the Set-up title line has no accompanying raster in the source DOCX.

LG Chem (Nanjing) ZEISS CrossBeam 550 DVIA-M1000 (231205R4) Installation Report
DVIA-M1000 handout archived as MB1000_231205R4_24.06.17 for LG Chem (Nanjing) and ZEISS CrossBeam 550. The public page reproduces the site header lines, bilingual summary rows, Overview line including the measurement dated 2024.06.26, the trip-record block (setup 2024.06.17 reported by Chaewon Lee vs measurement operator Byeonghun Cho), and three M1000 internal program screenshots (Vertical, Left to Right, Front to Back). No measurement summary table or Reference appendix appears in the source.