Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

YIMO N/A N/A N/A DVIA-MB1000 (240102R5) Installation Report
DVIA-MB1000 installation report (serial 240102R5). Published figures: tuning-request, allowable-vibration-spec, allowable-vertical-vc-curve, allowable-horizontal-vc-curve, vertical-transmissibility, left-to-right-transmissibility, front-to-back-transmissibility. Reference uses the standard Generic Vibration Criteria markdown table.

YIMO N/A N/A N/A DVIA-MB1000 (240102R5) Installation Report
DVIA-MB1000 installation report (serial 240102R5). Published figures: tuning-request, allowable-vibration-spec, allowable-vertical-vc-curve, allowable-horizontal-vc-curve, vertical-transmissibility, left-to-right-transmissibility, front-to-back-transmissibility. Reference uses the standard Generic Vibration Criteria markdown table.

Fuzhou University Thermo Fisher Talos F200 — DVIA-MB3000 (240201R4-1) Installation Report
DVIA-MB3000 active vibration isolation worksheet (serial 240201R4-1) for a Thermo Fisher Talos F200 TEM at Fuzhou University, with installation in Fuzhou (福州市). Setup 2024.06.07, reporting 2024.07.05; operator Byeonghun Cho (DAEIL SYSTEMS). Document Version: MB3000 internal program captures for Vertical, Left to Right, and Front to Back only; the Word header image above the summary table is omitted on the public page. No Reference / VC criteria appendix in the source handout.

YIMO FEI NOVA NanoSEM 450 FE-SEM DVIA-M1000 (240315R5) Installation Report
DVIA-M1000 installation report (serial 240315R5) for FEI NOVA NanoSEM 450 FE-SEM via YIMO. Overview states the platform is appropriately installed and functioning as intended. Tuning May 22, 2024; report written July 5, 2024. The published handout has no End User row (Prepared for blank), no Location detail beyond N/A, no Tuning Request section, no vibration specification section, and no measurement summary table. Equipment condition: The equipment is installed. Published figures: UI-program transmissibility (vertical, left-to-right, front-to-back) and an on-site equipment photo; Reference uses the standard Generic Vibration Criteria markdown table only (the source DOCX embed under Reference is not republished as an image).

YIMO Southern University of Science and Technology ZEISS Crossbeam 350 FIB-SEM DVIA-M1000 (240401R1-1) Installation Report
DVIA-M1000 installation report (serial 240401R1-1) for Southern University of Science and Technology in Shenzhen, China (YIMO). Overview states the platform is appropriately installed and functioning as intended. No measurement summary table on the published form. Equipment condition: The equipment is installed. Tuning Request UI capture and vertical / left-to-right / front-to-back transmissibility plots; Reference uses the standard Generic Vibration Criteria markdown table (no separate reference graphic).

YIMO Southern University of Science and Technology ZEISS GeminiSEM360 SEM DVIA-M1000 (240401R1-2) Installation Report
DVIA-M1000 installation report (serial 240401R1-2) for Southern University of Science and Technology in Shenzhen, China (YIMO). Overview states the platform is appropriately installed and functioning as intended. No measurement summary table on the published form. Equipment condition: The equipment is installed. Tuning Request UI capture and vertical / left-to-right / front-to-back transmissibility plots; Reference uses the standard Generic Vibration Criteria markdown table (no separate reference graphic).