Hitachi SU3500 SEM DVIA-MB1000 Installation
Installation Report
DVIA-M Series
04-06-2016

Hitachi SU3500 SEM DVIA-MB1000 Installation

Hitachi SU3500 SEM DVIA-MB1000 Installation

Hitachi SU8010 SEM DVIA-MB1000 Installation
Installation Report
DVIA-M Series
04-06-2016

Hitachi SU8010 SEM DVIA-MB1000 Installation

Hitachi SU8010 SEM DVIA-MB1000 Installation

Hitachi SU8010 DVIA-MB1000 (MB1000 P15) vibration environment measurement — Seoul National University of Science and Technology — 2016-01-12

2016 workbook for MB1000 program P15 (channel partner worksheet) measuring the vibration environment for a Hitachi SU8010 SEM at Seoul National University of Science and Technology (Hyeseong Hall, 2F electron microscopy lab). Published items follow Word §2a embed order after the omitted first-paragraph banner: equipment photograph, VC-CLASS floor vs isolation-top summary and Z/X/Y environment curves, then Z/X/Y built-in-program screenshots with transmissibility and autospectrum (table probe) captures. Separate “Autospectrum (floor)” placeholders appear in plaintext only; no fourth embedded figure per axis was present under word/media.

DVIA-M type (MB1000) installation test report — Nemo — 2015-10-30

MB1000 installation test worksheet for Nemo (measurement 2015-10-28, reported 2015-10-30 by DAEIL SYSTEMS • LIM JONG UK): VC-Class summary on floor versus active top, narrative bullets including FEI Korea site-readiness context, and fifteen figures — Result 1 internal-program transmissibility plus autospectrum-of-table and autospectrum-of-floor for Z/X/Y; Result 2 PULSE 1/3-octave Z/X/Y; Result 3 PULSE g-data Z/X/Y. Decorative title/header-only graphics from the Word handout are not published.

KRICT Building 10 L3 EMI room DVIA-MB3000 vibration environment measurement (September 2015)

Post-install vibration survey at Korea Research Institute of Chemical Technology comparing floor vs DVIA-MB3000 top plate in VC-Class for Z/X/Y axes, including annotated BASE/TOP locations and 1/3-octave velocity curves.

DVIA-M type (MB1000) Installation test — NEMO — 2015-09-03
Installation Report
DVIA-M Series
09-03-2015

DVIA-M type (MB1000) Installation test — NEMO — 2015-09-03

NEMO DVIA-M type (MB1000) Installation Test Report (installation and measurement on 2015-09-01, reporting on 2015-09-03 by LIM JONG UK, Daeil Systems). Installation Results Summary table and bullets follow the DOCX extract; figures follow paragraph-order §2a mapping — internal-program transmissibility Z/X/Y (rId6–8 → images 1–3), first PULSE 1/3-octave band Z/X/Y (rId9–11 → images 4–6), second PULSE 1/3-octave band Z/X/Y (rId12–14 → images 7–9).