Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
Filtered Case Studies

OXFORD AS400 NMR DVIA-MB1000/P75 (MC1000_P75) — DVIA-M Series vibration report (2018-04-10)
2018 field report after active mounting: VC-class summary (floor vs above active) and MB1000 internal program VC-class graphs (Z/X/Y), plus octave-band plots (floor vs above active). Six WebP figures; decorative title-block raster omitted. Reference is the standard Generic Vibration Criteria markdown table only.

FATRI-UTC ZEISS-Gemimi DVIA-MB1000 (P55) Installation Report — 2018.03.08
DVIA-MB1000 MB1000 program worksheet P55 for FATRI-UTC (Quanzhou, 1F analytical clean room) with a ZEISS-Gemimi column. Published materials include the site setup photo, VC-class summary (Floor F / Above Active G on Z–Y), MB1000 internal-program transmissibility plots for Z, X, and Y, and octave-band Floor vs Above Active plots for each axis. Field engineer Choi, HyoungMun (DAEIL SYSTEMS); measurement 2018-03-06; report date 2018-03-08.

Kolbenschmidt Shanghai Piston (KSSP) ZEISS EVO18 DVIA-MB1000 (MB1000 P56) China outbound report — 2018.01.02
Outbound installation worksheet for DVIA-MB1000 referenced as MB1000 P56 with ZEISS EVO18 at a corporate R&D lab in Shanghai (1F). Business trip 2017-12-27, traveler Choi Sung-won, report written 2018-01-02. The public page reproduces the VC-Class summary grid, the Korean narrative bullets, the on-site photograph after the title block, MB1000 internal-program captures for Z/X/Y, and vibration-environment plots for Z/X/Y. The decorative banner image above the centred title line in the DOCX is omitted. The “Image comparison” table labels PASSIVE/ACTIVE but contains no embedded figures in the source file.

Seohan Technology Research Institute JEOL JSM-IT500 DVIA-MB1000 (P54) Installation Report — 2018.01.02
DVIA-MB1000 P54 handout for a JEOL JSM-IT500 SEM at Seohan Technology Research Institute (3F analytical lab). Trip 2018-01-02, report 2018-01-03, field engineer Choi, Hyoung Mun (Daeil Systems). VC-class summary table, MB1000 internal-program Z/X/Y plots, and octave-band floor vs isolator-top comparisons. A small centred header decoration from the source layout is not republished.

Kolbenschmidt Shanghai Piston ZEISS evo18 DVIA-MB1000 (P56) Internal program worksheet — 2017.12.27
DVIA-MB1000 worksheet (program line MB1000 P56) with target equipment ZEISS-evo18 for end user Kolbenschmidt Shanghai Piston at 1th Floor. Business traveler Choi, SungWon; measurement on 2017.12.27 (Monday); workbook Date Created 18.01.02. The Overview line, VC-Class summary grid, and follow-on notes are taken verbatim from the DOCX text extract. MB1000 internal-program screenshots for Z, X, and Y axes and Octave Band Result plots use §2a embed mapping (image3–image8). Decorative bitmaps on the company title line (image1) and centred “MB1000_P56 … Set up” banner (image2) are not republished. The workbook has no Vibration specification or Reference headings; none were added.

Beijing Tsinghua University ZEISS Crossbeam 340 DVIA-MB1000 (MB1000 P10) internal program — 2017.12.20
DVIA-MB1000 MB1000 P10 worksheet for a ZEISS Crossbeam 340 at Tsinghua University (Beijing, 7th-floor lab). Trip 2017-12-17–19, report 2017-12-20, engineer Choi Hyoung Mun (DAEIL SYSTEMS). Publishes the VC-Class summary table, narrative measurement notes, the VC-Class curve figure (DOCX image2 under the centred title line), MB1000 internal-program Z/X/Y captures, and octave-band Z/X/Y plots (BASE: floor vs isolator top). Decorative title-strip raster (DOCX image1) is not republished. ISO/VC criteria are given as the standard site markdown table only.