Skip to main content

Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

Filtered Case Studies

455 case studies
Wangxiang ZEISS Sigma 300 DVIA-MB1000 MB1000 Internal Program (P179) — 2020.10.21

MB1000 program worksheet 200522R2-3 (P179) for ZEISS Sigma 300 in Hangzhou: setup summary tables, transmissibility summary at 2 / 5 / 10 Hz, and Signal-program internal performance captures for Z, X, and Y. The large centered graphic placed directly under the Word title line is omitted from the public page as a title-block decorative image.

Tier-1 Semiconductor FEI TF20 TEM DVIA-MB3000 (200623R1) Installation Worksheet — 2020.10.21

DVIA-MB3000 (serial 200623R1) active-mount vibration worksheet after TF20-FEI TEM installation at Tier-1 Semiconductor. Measurement date 2020.10.21; internal-program Z/X/Y transmissibility and coherence plots plus installation photograph; summarized frequency picks at 2 Hz, 5 Hz, and 10 Hz with omnidirectional assessment.

Schaeffler DVIA-MB1000 (P914, 200730R1) Internal program performance — 2020.10.05

DVIA-MB1000 worksheet P914 (platform serial 200730R1) at Schaeffler; measurement and reporting dated 2020.10.05 (operator Choi, HyoungMun, Daeil System). Summary transmissibility table and Korean site notes follow the DOCX; MB1000 internal-program plots are published under Z, X, and Y axis headings. The centred title-line decorative raster is not republished.

ZEISS GEMINI SEM 500 DVIA-MB1000 (P132 / 190614R2) Internal program performance — 2020.09.24

DVIA-MB1000 worksheet P132 (serial 190614R2) for a ZEISS_GEMINISEM 500 at Xi'an Jiaotong University (measurement and reporting dated 2020.09.23–2020.09.24; operator Choim, HyoungMun, Daeil System). Summary table transmissibility values and overview text follow the DOCX; MB1000 internal-program screenshots align with Z axis, X axis, and Y axis headings per §2a embed mapping (rId9–11 → image2–4). The decorative raster on the centred MB1000 title line (rId8 / image1) is not republished.

FEI Apreo C DVIA-MB1000 (P162 / 200414R1) Internal program performance — 2020.09.18

DVIA-MB1000 worksheet P162 (serial 200414R1) for a FEI Apreo C at NORINCO GROUP in Zhanjiang (measurement and reporting dated 2020.09.17–2020.09.18; operator Choim, HyoungMun, Daeil System). Summary table transmissibility values and overview text follow the DOCX; MB1000 internal-program screenshots align with Z axis, X axis, and Y axis headings per §2a embed mapping. The decorative raster on the centred MB1000 title line is not republished.

Baosteel Zhanjiang Zeiss Sigma 300 DVIA-MB1000 (200522R2-4 · P183) Internal program worksheet — 2020.09.11

DVIA-MB1000 worksheet (serial 200522R2-4, program line MB1000 P183) with target equipment Zeiss Sigma 300 for Baosteel Zhanjiang. Operator Munho Noh (Daeil System, research engineer); setup and reporting on 2020.09.11; measurement the same calendar day at zhanjiang with the Overview text and fixed-frequency transmissibility table copied from the DOCX; MB1000 internal-program screenshots under Z axis, X axis, and Y axis follow §2a embed mapping (image2–4). Decorative bitmap on the centred “MB1000_200522R2-4(P183) Set up” title line is not republished. The sheet has no Vibration specification, Reference, or Measurement Summary headings beyond “Summary of measurement results”; none were added.