Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1246 case studies
Thermo Fisher Scientific TFS Helios (Brigham Young University) DVIA-ML1000 (250708R4-3) Installation Report

Vibration isolation installation report for DVIA-ML1000 serial 250708R4-3 beneath a Thermo Fisher Scientific Helios platform at BYU Electron Microscopy Facility: VC-F vertical and VC-G horizontal vibration criteria; floor versus DVIA comparison plots with transmissibility; onsite installation and serial photos.

Brigham Young University TFS Apreo MLP 1000 Installation Report
Installation Report
DVIA-MLP Series
09-11-2025

Brigham Young University TFS Apreo MLP 1000 Installation Report

Installation Report Vibration Isolation MLP 1000 TFS Apreo A 110

Brigham Young University TFS Verios MLP 1000 Installation Report
Installation Report
DVIA-MLP Series
09-11-2025

Brigham Young University TFS Verios MLP 1000 Installation Report

Installation Report Vibration Isolation MLP 1000 TFS Verios A 112. Prepared for Felipe Rivera (BYU). PO Y00012484.

DVIA-ML1000 (250227R2) Installation Report
Installation Report
DVIA-M Series
09-05-2025

DVIA-ML1000 (250227R2) Installation Report

DVIA-ML1000 installation report (serial 250227R2).

ZEISS FE-SEM Sigma 360 DVIA-ULFB700 (250529R5) Installation Report
Installation Report
DVIA-ULF Series
09-05-2025

ZEISS FE-SEM Sigma 360 DVIA-ULFB700 (250529R5) Installation Report

DVIA-ULFB700 (S/N 250529R5) active vibration isolation platform installation report for ZEISS FE-SEM Sigma 360. Chaewon Lee (DAEIL SYSTEMS) tuned on September 4, 2025; report written September 5, 2025. End User and Location not disclosed in the report form (N/A). Measurement summary table and UI-program VC curves, autospectra, and transmissibility vertical / left-to-right / front-to-back with equipment installed/Turned off; equipment photo and markdown VC Reference (no EMF illustration).

Chinese Academy of Sciences Institute of Semiconductors Thermo Fisher Helios 5 CX DVIA-M1000 (250619R4) Installation Report

DVIA-M1000 installation report — Thermo Fisher FIB-SEM Helios 5 CX (serial 250619R4), Institute of Semiconductors, Chinese Academy of Sciences in Beijing (YIMO channel). Overview states the platform is appropriately installed and functioning as intended. The on-site form has no vibration-specification section. Published figures: tuning-request UI capture, floor vs DVIA-M1000 Transmissibility (vertical, left-to-right, front-to-back), on-site equipment photo; Reference uses the standard Generic Vibration Criteria markdown table. Equipment Condition The equipment is installed/Turned off. No VC curves or Autospectrum plots appear in this report.