Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies
Tier-1 Semiconductor Hwaseong NRD Line 8F Bruker NM-VI DVIA-P4000 (036174) Installation Report
Tier-1 Semiconductor Hwaseong NRD Line 8F Bruker Photomask Repair NM-VI DVIA-P4000 (036174) Installation Report

Tekscend Photomask CLB ZEISS MeRiT MG neo DVIA-P2200 Installation Report
Tekscend Photomask CLB ZEISS X-ray Microscope MeRiT MG neo DVIA-P2200 installation report (tuning and vibration measurement).

Tier-1 Semiconductor Thermo Fisher Scientific S/TEM Spectra 300 DVIA-ML3000 (241119R1) Installation Report
DVIA-ML3000 installation report (serial 241119R1) for Thermo Fisher Scientific S/TEM Spectra 300 via YIMO at Tier-1 Semiconductor, Beijing. Overview states the platform is appropriately installed and functioning as intended. Second tuning trial; tuning and report written September 15, 2025. Equipment condition: The equipment is Turned on/IDLE. The published handout has no separate vibration specification or measurement summary table. Tuning Request field is blank (N/A). Data and Image publishes vertical, left-to-right, and front-to-back transmissibility and an on-site equipment photo; Reference uses the standard Generic Vibration Criteria markdown table only (reference vector graphic not republished).

DVIA-ML1000 (241120R5) Installation Report
DVIA-ML1000 installation report (serial 241120R5).

YIMO ZEISS FE-SEM Sigma 360 DVIA-M1000 (250204R4) Installation Report
DVIA-M1000 installation report (serial 250204R4) for ZEISS FE-SEM Sigma 360 via YIMO. Overview states the platform is appropriately installed and functioning as intended. End user and location are not filled on the published form (N/A). Equipment condition: The equipment is Turned on/IDLE. Tuning request field is blank (N/A). Transmissibility plots (vertical, left to right, front to back), on-site equipment photo, and Reference with Generic Vibration Criteria as a markdown table (reference EMF graphic omitted).

Taixing Electronics Circuit ZEISS FE-SEM Sigma 360 DVIA-M1000 (250604R1) Installation Report
DVIA-M1000 installation report — ZEISS FE-SEM Sigma 360 (serial 250604R1) for Taixing Electronics Circuit in Ayutthaya, Thailand. Overview states the platform is appropriately installed and functioning as intended. Equipment condition: The equipment is Turned on/IDLE. Published figures: YIMO coordination summary capture, UI-program Transmissibility (vertical, left-to-right, front-to-back); the source handout has no vibration-specification heading, no measurement summary table, and no VC or Autospectrum figures. Equipment picture could not be taken per on-site note.