DVIA-ML1000 (241120R5) Installation Report
Installation Report
DVIA-M Series
09-15-2025

DVIA-ML1000 (241120R5) Installation Report

DVIA-ML1000 installation report (serial 241120R5).

ZEISS FE-SEM Sigma 360 DVIA-M1000 (250204R4) Installation Report

DVIA-M1000 installation report (serial 250204R4) for ZEISS FE-SEM Sigma 360. Overview states the platform is appropriately installed and functioning as intended. End user and location are not filled on the published form (N/A). Equipment condition: The equipment is Turned on/IDLE. Tuning request field is blank (N/A). Transmissibility plots (vertical, left to right, front to back), on-site equipment photo, and Reference with Generic Vibration Criteria as a markdown table (reference EMF graphic omitted).

Taixing Electronics Circuit ZEISS FE-SEM Sigma 360 DVIA-M1000 (250604R1) Installation Report

DVIA-M1000 installation report — ZEISS FE-SEM Sigma 360 (serial 250604R1) for Taixing Electronics Circuit in Ayutthaya, Thailand. Overview states the platform is appropriately installed and functioning as intended. Equipment condition: The equipment is Turned on/IDLE. Published figures: coordination summary capture, UI-program Transmissibility (vertical, left-to-right, front-to-back); the source handout has no vibration-specification heading, no measurement summary table, and no VC or Autospectrum figures. Equipment picture could not be taken per on-site note.

Thermo Fisher Scientific TFS Helios (Brigham Young University) DVIA-ML1000 (250708R4-3) Installation Report

Vibration isolation installation report for DVIA-ML1000 serial 250708R4-3 beneath a Thermo Fisher Scientific Helios platform at BYU Electron Microscopy Facility: VC-F vertical and VC-G horizontal vibration criteria; floor versus DVIA comparison plots with transmissibility; onsite installation and serial photos.

Brigham Young University TFS Apreo MLP 1000 Installation Report
Installation Report
DVIA-MLP Series
09-11-2025

Brigham Young University TFS Apreo MLP 1000 Installation Report

Installation Report Vibration Isolation MLP 1000 TFS Apreo A 110

Brigham Young University TFS Verios MLP 1000 Installation Report
Installation Report
DVIA-MLP Series
09-11-2025

Brigham Young University TFS Verios MLP 1000 Installation Report

Installation Report Vibration Isolation MLP 1000 TFS Verios A 112. Prepared for Felipe Rivera (BYU). PO Y00012484.