Baosteel R&D ZEISS EVO10 DVIA-MB1000 (200522R2-1 · P166) Internal program worksheet — 2020.12.15
DVIA-MB1000 worksheet (serial 200522R2-1, program line MB1000 P166) with target equipment ZEISS-EVO10 for end user Baosteel at Baosteel R&D Center (2Floor). Operator Choi HyoungMun (Daeil System, research engineer); setup, measurement, and reporting on 2020.12.15; the Overview text and fixed-frequency transmissibility table follow the DOCX verbatim; MB1000 internal-program screenshots under Z axis, X axis, and Y axis use §2a embed mapping (image2–4). Decorative bitmap on the centred “MB1000 P166 … 200522R2-1” title line (image1) is not republished. The workbook has no Vibration specification or Reference headings; none were added.

Baosteel R&D Center ZEISS Sigma 300 DVIA-MB1000 (P205 201116R2) Internal Program Performance — 2020.12.15
DVIA-MB1000 internal program MB1000 P205 (201116R2) at Baosteel R&D Centre 3F, target equipment ZEISS Sigma 300. Includes transmissibility summary and Z / X / Y internal-program curves as published in the source. The centred title-line bitmap between the report heading row and setup tables is not republished.

ZEISS GEMINI DVIA-MB1000 (P168 / 191219R3-1) NEMO worksheet — 2020-12-09
NEMO handout MB1000 P168 NEMO 20.12.09.docx — target ZEISS-GEMINI, reporting 20.12.09 (setup 20.12.07). Transmissibility summary at 2/5/10 Hz and MB1000 internal-program Z/X/Y screenshots follow DOCX §2a mapping (rId9–11 → image2–4); the centred title-line ornament (rId8 / image1) is not republished.

Remote tuning — Nanjing University High-power Telescope DVIA-MB1000 (200914R2 P206) — 2020.12.09
-channel MB1000 internal-program worksheet for DVIA-MB1000 serial 200914R2 (platform notation P206) at Nanjing University with High-power Telescope as the stated target equipment. Operator Munho Noh (Daeil System, research engineer); setup, measurement, and reporting on 2020.12.09; business-trip window reproduced verbatim from the Word form. Published figures are the MB1000 internal-program Z/X/Y performance screens plus the transmissibility summary table copied from the form; the title-line header raster (`image1`) is omitted from the public gallery. The source document has no Reference / Generic Vibration Criteria appendix.

TESCAN DVIA-MB1000 Installation Report — onsite measurement (SN 200521R4, 2020-12-04)
TESCAN tool on DVIA-MB1000 SN 200521R4 — program, measurement 2020-12-01, report 2020-12-04. Published imagery: on-site TESCAN equipment photo, then MB1000 internal program Z / X / Y plots and transmissibility summary table.

Zili Co., Ltd. Zeiss Sigma 500 DVIA-MB1000 (200715R3-2 · P187) Remote measurement — Internal program plots — 2020.12.02
DVIA-MB1000 serial 200715R3-2 (project P187) for Zeiss Sigma 500 reported via /channel partner; installation site table lists Shaoxing with END USER 自立股份 (Zili Co., Ltd.). Measurement date and place of measurement are Shaoxing; figures follow Z axis, X axis, and Y axis internal-program screenshots as in Word. The ornamental centered photo immediately under the title block is not republished.