Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
Filtered Case Studies

ZEISS Sigma 300 DVIA-MB1000 (P256 / 210604R3) Internal program performance — 2021.11.24
DVIA-MB1000 worksheet P256 (serial 210604R3) for ZEISS Sigma 300 at Xiamen Faratronic (measurement and reporting dated 2021.11.24; operator Choi, HyoungMun, Daeil System). Summary table transmissibility values and overview text follow the DOCX; MB1000 internal-program screenshots align with Z axis, X axis, and Y axis headings per §2a embed mapping. The decorative raster on the centred MB1000 title line is not republished.

Xi'an Jingke ZEISS GeminiSEM 300 DVIA-MB1000 (210326R6) Installation Report — 2021.11.23
MB1000 field worksheet for isolator serial 210326R6 (MB1000 P213) with ZEISS GeminiSEM 300 in Xi’an: setup program capture, transmissibility summary at 2/5/10 Hz, and MB1000 internal-program Z/X/Y plots. Measurement dated 21.11.22 per the form; reporting 21.11.23; operator Kim, Doohyun (Daeil System).

Zeiss EVO10 DVIA-MB1000 (210903R3) Internal Program Performance — 2021.11.11
DVIA-MB1000 serial 210903R3 — job reference P252, target equipment Zeiss-EVO10, onsite work 2021-11-10 with report date 2021-11-11. Internal-program plots follow Z axis, X axis, and Y axis headings as in the source. The title-block raster mapped to "MB1000 P252 210903R3" in Word is not republished.

BOE ZEISS CROSSBEAN350 DVIA-MB1000 (210705R1) Internal Program Performance — 2021.11.05
DVIA-MB1000 serial 210705R1 internal-program worksheet for BOE with target equipment ZEISS CROSSBEAN350. Setup 2021-11-04, reporting 2021-11-05; operator Choi HyoungMun (DAEIL SYSTEMS research engineer). Includes transmissibility summary table at 2 / 5 / 10 Hz and Z / X / Y internal-program plots under the axis captions from the source.

ZEISS CROSSBEAM350 DVIA-MB1000 (210705R1 · MB1000 P244) Internal Program Performance — 2021.11.05
DVIA-MB1000 internal-program worksheet (program line MB1000 P244) with platform serial 210705R1 and target equipment ZEISS CROSSBEAN350 for end user BOE. Operator Choi HyoungMun (Daeil System); setup 2021-11-04, reporting 2021-11-05, business trip line 17.12.27~17.12.29. Transmissibility summary and MB1000 internal-program Z, X, and Y screenshots follow the DOCX §2a head↔embed mapping (no decorative title-only raster in this handout).

SILAN ZEISS CROSSBEAN350 MB1000 P250 DVIA-MB1000 Internal Program — SN 210812R2 — 2021.10.28
DVIA-MB1000 worksheet (program line MB1000 P250, platform serial 210812R2) for ZEISS CROSSBEAN350 at SILAN. Setup, measurement, and reporting dates read 2021-10-28 in the workbook; DOCX ingest file labeled 2021-10-29. The centred graphic under **MB1000 P250 210812R2** (image1) is a title-block ornament and not republished; transmissibility table values and MB1000 internal-program Z / X / Y screenshots follow DOCX §2a (image2–4) under matching axis headings.