TESCAN MIRA LMS FE-SEM DVIA-ML1000 Installation Report
Installation Report
DVIA-M Series
10-15-2026

TESCAN MIRA LMS FE-SEM DVIA-ML1000 Installation Report

DVIA-ML1000 installation report (serial 260730R5) for a TESCAN MIRA LMS FE-SEM at Wuhan University of Science and Technology in Wuhan. Tuning and vibration measurement were performed on 2026.10.15 with the SEM in the Idle state; after the first tuning trial the isolator meets the vibration specification on all three axes.

ZEISS EVO 15 SEM DVIA-ULF700 Installation Report
Installation Report
DVIA-ULF Series
10-15-2026

ZEISS EVO 15 SEM DVIA-ULF700 Installation Report

Installation report of DVIA-ULF700 (S/N 260901R1) at the Delta Electronics site in Shanghai, serving a ZEISS EVO 15 SEM. Tuning and vibration measurement were performed in the Idle state with data in Autospectrum format; the isolator met the EVO 15 vibration specification in all three axes.

AIPIN STM DVIA-ML1000 Re-Tuning Installation Report
Installation Report
DVIA-M Series
10-13-2026

AIPIN STM DVIA-ML1000 Re-Tuning Installation Report

DVIA-ML1000 re-tuning installation report (serial 221024R3) for an Aipin Instrument Technology AIPIN STM at the National Center for Nanoscience and Technology in Beijing. The 5th tuning trial (re-tuning) was performed on 2026.10.13 in response to isolator instability reported by the customer. With the AIPIN STM in the IDLE state, the isolator reached VC-G (Vertical) and VC-E (Left to Right, Front to Back), and floor vibration was attenuated on all axes except the 12–16 Hz band on the horizontal axes; as no vibration specification was available from the manufacturer or the end user, no PASS/FAIL determination is made.

ZEISS Gemini SEM 560 DVIA-ULF1000 Installation Report
Installation Report
DVIA-ULF Series
10-13-2026

ZEISS Gemini SEM 560 DVIA-ULF1000 Installation Report

Installation report of DVIA-ULF 1000 (S/N 250923R4) at Xi’an for (End User: Xi’an Jiaotong University Testing Center), serving a ZEISS Gemini SEM 560. Tuning and vibration measurement were performed in the Idle state with data in Autospectrum format; a resonance around 2–3 Hz on the horizontal axes was observed, and all measured axes passed against the customer vibration specification.

Hyundai Motor Company Keyence VHX-X1 Digital Microscope DVIA-TD45 (260722R4) Installation Report

Installation report for the DVIA-TD45 (serial 260722R4) installed at Hyundai Motor Company's Namyang Research Institute under a Keyence VHX-X1 digital microscope. Re-tuning was performed for stability while the equipment on top moves or the load changes, and vibration measurements in the IDLE state showed the platform top at VC-C to VC-E, improved from the floor (VC-A to VC-B).

LG Innotek NanoSystem White-Light Interferometer DVIA-ULF1000 Demonstration Report

LG Innotek (End User LG Innotek, 2F cleanroom of Gumi Plant 4) NanoSystem precision measurement equipment (white-light interferometer) DVIA-ULF1000 demonstration (demo test) report — after installation, tuning and vibration measurement were performed in the IDLE state and represented in VC Curve format. The platform achieved VC-F (Vertical), VC-E (Left to Right), and VC-D (Front to Back), confirming excellent vibration isolation performance. Per-axis autospectra and VC Curves, and installation photos are published.