Nissan Chemical Helios G4 UC DVIA-MB1000 Installation Report — MB1000 P124 (2019-06-27)

China trip report for MB1000 project P124 at Nissan Chemical F1 with Thermo Fisher Scientific Helios G4 UC. Trip date 2019-06-24; report dated 2019-06-27. Published imagery: site/equipment photograph, MB1000 internal program Z / X / Y results, and vibration environment measurement Z / X / Y plots.

MFLEX Suzhou ZEISS Sigma500 DVIA-MB1000 (MB1000 P109) China business trip worksheet — 2019.06.27

Korean-format China business-trip worksheet MB1000 P109 for DVIA-MB1000 with target equipment ZEISS Sigma500 at MFLEX Suzhou MFC3 F4 (end user MFLEX). Business trip 19.06.25; operator line names Choi, Sungwon; report dated 19.06.27. The public page publishes the installation photograph embedded after the title block (DOCX Word image2, §2a; 1136×498), MB1000 internal-program screenshots Z / X / Y (image3–5), and vibration-environment plots Z / X / Y (image6–8). The narrow decorative title-strip bitmap Word image1 (471×214) is omitted.

Thermofisher Scientific Helios G4 UC DualBeam HR-S/TEM DVIA-MB1000 Installation Report

Thermofisher Scientific Helios G4 UC DualBeam HR-S/TEM

BOE ZEISS Gemini 2 Crossbeam 550 DVIA-MB1000 (MB1000 P112) Internal program worksheet — 2019.05.24

DVIA-MB1000 worksheet (MB1000 P112) for BOE with target equipment ZEISS-Gemini2 Crossbeam550 at BOE, 3th FLOOR. Date of business trip 19.05.22; business traveler Choi, HyoungMun; workbook Date Created 19.05.24. Measurement date 19.05.22 (WED) with Rater Daeil System, Manager Choi , Hyoung Moon. The VC-Class summary grid and narrative lines follow the DOCX text extract. Published screenshots use DOCX §2a head↔embed mapping: on-site image under the title head (image1), MB1000 internal-program Z / X / Y (image2–4), and Octave Band Result Z / X / Y for BASE Floor vs TOP Above Active (image5–7). The source has no Vibration specification or Reference section; none was added.

Ningbo University of Technology JEOL JEM-2100F DVIA-MB1000 Installation Report — SN 190410R2 (2019-05-20)

JEOL JEM-2100F on DVIA-MB1000 SN 190410R2 at Ningbo University of Technology — measurement 2019-05-15, report 2019-05-20. Published imagery: site equipment photo, MB1000 internal program Z / X / Y results, and octave-band Z / X / Y plots (floor vs above active).

Ningbo University of Technology JEOL JEM-2100F DVIA-M3000 MB1000 P126 China trip report — 2019.05.20

Trip worksheet MB1000_P126 dated 2019-05-20 for JEOL JEM-2100F at Ningbo University of Technology (Classroom building2 F1 2-101). Business trip 2019-05-15, operator Choi, Sung-won. Published items follow the source structure: equipment photograph on DVIA-M3000 base, VC-Class summary, magnetic-field AC/DC tables, MB1000 internal-program Z/X/Y captures, 1/3-octave vibration-environment Z/X/Y plots, and magnetic-field screen captures before and after compensation. The first raster embedded under the title line in the DOCX carried no usable figure content and is omitted.