ZEISS Crossbeam 550 DVIA-MB1000 (MB1000 P145 / 191022R1) Internal Program — Singapore IME — 2020.06.19

Nanoserv project file MB1000 P145: MB1000 internal-program worksheet (title block MB1000_191022R1) for ZEISS Crossbeam 550 at Singapore IME Level 1. Setup on 2020-06-19, report dated 2020-06-23, measurement by Manager Doohyun, Kim (Daeil System). Publishes the site photograph after the title block, the VC-Class summary table as issued (Floor and Above Active with empty VC-Class cells), and MB1000 program screenshots under the Z, X, and Y axis headings in the same order as the source DOCX.

Tier-1 Semiconductor TESCAN-FE SEM DVIA-MB1000 (MB1000 program, P123) Installation Report — 2020.06.19

DVIA-MB1000 MB1000 program handout for a TESCAN-FE SEM site at a Tier-1 Semiconductor Icheon R&D Center 1F location (program P123). Setup metadata, measurement chain photos, VC-class summary table, MB1000 internal-program plots per axis, and octave-band floor vs above-active plots. Generic Vibration Criteria are published as the site markdown table only (Korean criteria raster and VC nomograph from the Word appendix are not uploaded). Field engineer Choi, Hyoung Mun (DAEIL SYSTEMS); measurement and report 2020-06-19.

TESCAN AMBER DVIA-MB1000 (P161) Internal Program Performance — 2020.06.17

DVIA-MB1000 program MB1000 P161 — target equipment TESCAN AMBER (isolator tag MB1000_200306R1 in the worksheet). End user and installation site fields are N/A in the source form. Internal-program plots follow Z axis, X axis, and Y axis as embedded under those headings; the centered graphic under the setup title is not republished.

FEI SEM DVIA-MB1000 Installation Report — MB1000 P142, SN 190916R4 (2020.06.04)

MB1000 program P142 worksheet for an FEI SEM on DVIA-MB1000 serial 190916R4. Setup 2020-06-03; report 2020-06-04; operator Choi, HyoungMun (Daeil System). Publishes the on-site equipment photo, VC-Class summary table as issued (empty floor / above-active cells), the “Good omnidirectional performance.” line, and MB1000 internal-program plots for Z, X, and Y.

University of Science and Technology of China (Hefei) STM DVIA-MB3000 (191129R1) Worksheet — May 27, 2020

DVIA-MB3000 (serial 191129R1) worksheet dated May 26–27, 2020 at the University of Science and Technology of China (Hefei) with STM as the target equipment. After active mounting, the vibration environment was checked; measurement notes, a VC-class summary grid, qualitative “Good omnidirectional performance” result, and MB3000 internal program performance curves (Z, X, Y) are published. Operator Choi Hyoung-mun (DAEIL SYSTEMS).

ZEISS GeminiSEM300 DVIA-MB1000 Program (P115 / MB1000_190123R1) Installation Report — 2020.05.12

MB1000 internal-program handout for ZEISS GeminiSEM300 at Northwest Polytech University (Word title MB1000_190123R1): overview, measurement summary table with qualitative note, and MB1000 internal-program Z/X/Y performance plots. The graphic inserted in the title block before the university name line is omitted as cover decoration; the source file has no VC comparison curves or Reference section.