TESCAN Korea LB Semicon Amber X GMH DVIA-MB1000 (221202R2) Installation Report

TESCAN Korea installation worksheet for AMBER X GMH on DVIA-MB1000 (221202R2) at LB Semicon Pyeongtaek (4F cleanroom). VC curves and transmissibility by axis.

Tier-1 Semiconductor Hwaseong ZEISS GeminiSEM 460 DVIA-MB1000 (230110R2) Installation Report

DVIA-MB1000 installation report (serial 230110R2) for ZEISS GeminiSEM 460, prepared for ZEISS KOREA, with tuning and reporting in July 2023 at Tier-1 Semiconductor Hwaseong (11Line 4F development analysis laboratory). Summary of vibration results tabulates floor vs active VC-curve grades by axis and band; Data and Image publishes Z/X/Y VC curves and transmissibility plots. Decorative header raster and the reference-line graphic are omitted; Reference uses the standard Generic Vibration Criteria markdown table only.

DVIA-MB1000 (230501R3-2) Installation Report
Installation Report
DVIA-M Series
05-15-2026

DVIA-MB1000 (230501R3-2) Installation Report

Compact MB1000 handout worksheet (serial 230501R3-2). The form leaves target equipment unstated while place of installation and remark read as typed; end user carries a lone dash placeholder. Overview keeps the DVIA-MB1000 wording with measurement site and equipment-model labels open after the colon. Decorative header raster is omitted (no standalone cover blob in DOCX media). Published figures are the internal-program Vertical, Left to Right, and Front to Back screenshots; Reference uses the standard Generic Vibration Criteria markdown table only.

DVIA-MB1000 (230501R3-3) Installation Report
Installation Report
DVIA-M Series
05-15-2026

DVIA-MB1000 (230501R3-3) Installation Report

DVIA-MB1000 worksheet (serial 230501R3-3): compact MB1000 internal-program Transmissibility screenshots for Vertical, Left to Right, and Front to Back. Several form fields were unset in the source (target equipment, site, end user); public copy uses N/A. The issued Word file has no Reference / Generic Vibration Criteria appendix — that section is omitted here. Decorative header graphics from the template, if any, were not published.

POSCO Global R&D Center JEOL JSM-7001F DVIA-MB1000 (230518R2) Installation Report

DVIA-MB1000 installation report (serial 230518R2) for JEOL JSM-7001F at POSCO Global R&D center (Songdo). Summary of vibration results (VC-class table), Z/X/Y VC curves and transmissibility plots; Reference uses the standard Generic Vibration Criteria markdown table (reference graphic omitted). Decorative header image from the Word file is not published.

Jinhae Armed Forces Financial Management Command ZEISS FE-SEM EVO10 DVIA-MB1000 (230704R4) Installation Report

DVIA-MB1000 installation report (serial 230704R4) for ZEISS FE-SEM EVO10 at Jinhae Armed Forces Financial Management Command. Published figures: ZEISS EVO10 specification VC curve (equipment vibration limits), Vertical / Left-to-right / Front-to-back Transmissibility and VC curves. Reference uses the standard Generic Vibration Criteria markdown table only (no separate reference graphic).