Schaeffler DVIA-MB1000 (P914, 200730R1) Internal program performance — 2020.10.05

DVIA-MB1000 worksheet P914 (platform serial 200730R1) at Schaeffler; measurement and reporting dated 2020.10.05 (operator Choi, HyoungMun, Daeil System). Summary transmissibility table and Korean site notes follow the DOCX; MB1000 internal-program plots are published under Z, X, and Y axis headings. The centred title-line decorative raster is not republished.

ZEISS GEMINI SEM 500 DVIA-MB1000 (P132 / 190614R2) Internal program performance — 2020.09.24

DVIA-MB1000 worksheet P132 (serial 190614R2) for a ZEISS_GEMINISEM 500 at Xi'an Jiaotong University (measurement and reporting dated 2020.09.23–2020.09.24; operator Choim, HyoungMun, Daeil System). Summary table transmissibility values and overview text follow the DOCX; MB1000 internal-program screenshots align with Z axis, X axis, and Y axis headings per §2a embed mapping (rId9–11 → image2–4). The decorative raster on the centred MB1000 title line (rId8 / image1) is not republished.

FEI Apreo C DVIA-MB1000 (P162 / 200414R1) Internal program performance — 2020.09.18

DVIA-MB1000 worksheet P162 (serial 200414R1) for a FEI Apreo C at NORINCO GROUP in Zhanjiang (measurement and reporting dated 2020.09.17–2020.09.18; operator Choim, HyoungMun, Daeil System). Summary table transmissibility values and overview text follow the DOCX; MB1000 internal-program screenshots align with Z axis, X axis, and Y axis headings per §2a embed mapping. The decorative raster on the centred MB1000 title line is not republished.

Baosteel Zhanjiang Zeiss Sigma 300 DVIA-MB1000 (200522R2-4 · P183) Internal program worksheet — 2020.09.11

DVIA-MB1000 worksheet (serial 200522R2-4, program line MB1000 P183) with target equipment Zeiss Sigma 300 for Baosteel Zhanjiang. Operator Munho Noh (Daeil System, research engineer); setup and reporting on 2020.09.11; measurement the same calendar day at zhanjiang with the Overview text and fixed-frequency transmissibility table copied from the DOCX; MB1000 internal-program screenshots under Z axis, X axis, and Y axis follow §2a embed mapping (image2–4). Decorative bitmap on the centred “MB1000_200522R2-4(P183) Set up” title line is not republished. The sheet has no Vibration specification, Reference, or Measurement Summary headings beyond “Summary of measurement results”; none were added.

Shandong Lanxiang Zeiss Evo 18 DVIA-MB1000 (200522R7 · P163) Remote measurement — Internal program plots — 2020.09.10

DVIA-MB1000 serial 200522R7 (project P163) for Zeiss Evo 18 reported by /channel partner; installation table lists SHANDONG and end user 山东蓝翔 while the measurement block lists Place of measurement: Shangdong. Figures follow Z axis, X axis, and Y axis per Word; the raster under the title line after `(MB1000_200522R7(P163) Set up)` is not republished.

Hitachi HT7800 DVIA-MB1000 (P173 / 191219R3-4, Nimo remote tuning) — 2020.09.03

DVIA-MB1000 worksheet P173, isolator serial 191219R3-4, for Hitachi HT7800. Remote tuning handout dated setup 2020-09-02 and reporting 2020-09-03 (operator Choi, HyoungMun, Daeil System). The DOCX title line reads MB1000_P173; the VC-Class summary table cells are empty in the source as issued; Z / X / Y captions are followed by MB1000 internal-program screenshots uploaded as figure_01–03. The raster under the centred Set up title is decorative and is not republished.