Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

Hanyang University M-1000 P8 vibration environment survey — 2014-12-29
Vibration environment survey for the M-1000 P8 platform at Hanyang University (FTC Building, 2F): FEI SEM load with passive/internal setup only, VC-Class summary (ACTIVE state) for Z/X/Y at Base and Top, narrative notes from the result summary, and VAAV program captures for Passive and FFF axes. OCTAVE BAND and Active Z/X/Y sections appear in the issued form without embedded plots.

Hanyang University FEI SEM DVIA-MB1000 (MB1000 P8) vibration environment measurement — 2014-12-29
2014 workbook for MB1000 program P8 measuring vibration environment versus VC-Class criteria for an FEI SEM at Hanyang University College of Engineering (2014-12-29, Choi Sung-won). The Word-first-paragraph raster banner was omitted per DOCX §2a; published figures follow §2a order: VC-Class summary graphic immediately after the measurement-position paragraph, then Active Z/X/Y octave-band plots under OCTAVE BAND.

Korea University M1000 P7 vibration survey — 2014-07-25
Vibration environment worksheet for Korea University (College of Engineering industry–university building, 2F) after M-1000 P7 isolator work with an FEI SEM: measurement conditions, VC-Class and transmissibility summary table, discussion notes (including FEI comments, follow-up measurement plans, tuning observations, passive-state peak notes), VAAV captures (Passive Z/X/Y and FFF Z/X/Y), plus transmissibility and octave-band charts rasterized from Word-exported PDF pages (embedded OOXML charts). Decorative title-block raster at the document start (Word image1) is not published.

FEI SEM LSM M-1000 P4 vibration environment measurement — 2014-07-08
2014 measurement with an FEI SEM on an M-1000 P4 isolation platform at the LSM fourth-floor site: ACTIVE VC-Class summary on floor (base) versus platform top, narrative observations from the handout, one site photograph, transmissibility plots for Z/X/Y, and 1/3 octave velocity plots for Active Z/X/Y. Decorative header artwork from the DOCX is omitted from the public page.

LS Mtron — M-1000 P4 vibration measurement with FEI SEM (2014-07-08)
Vibration environment worksheet dated 2014-07-08 for the M-1000 P4 platform with FEI SEM at LS Mtron (4th floor): measurement-location diagram, VC-class summary with transmissibility at 10 Hz, narrative interpretation bullets, six VAAV program captures (Passive and FFF states, Z/X/Y), transmissibility plots (Z and X together; Y on a dedicated view), and 1/3 octave-band Active Z/X/Y curves reproduced in the same layout as the handout charts.

Bruker BioScience demo room — M-1000 P2 vibration environment measurement — 2014-06-18
2014-06-18 vibration environment worksheet at Kins Tower 15F Bruker BioScience demo room (engineer Choi Seong-won, DAEIL SYSTEMS): overview and measurement conditions while Carl Zeiss-mounted equipment was running, VC-Class summary on base versus isolator top under ACTIVE control, four narrative bullets from the handout, two site photographs of sensor placement, six VAAV captures (Passive Z/X/Y and FFF Z/X/Y), passive versus active transmissibility plots exported from embedded Word charts (Z+X combined page, Y-axis page), and 1/3 octave-band active plots (Z+X combined page, Y-axis page). Decorative header bitmap before the title in the DOCX is not republished. Generic vibration criteria are given as the standard markdown table only.