Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

ZEISS SIGMA HD DVIA-M1000 Installation Test Data — Qualcomm — 2017.10.26
2017 handout for DVIA-M type (MB1000) installation test data at Qualcomm with ZEISS SIGMA HD: installation and measurement 2017.10.24, reporting 2017.10.26, operator CHOI, HYOUNGMUN (DAEIL SYSTEMS). Publishes transmissibility-with-coherence plots (Z, X, Y) and octave-band results (Z, X, Y). A decorative raster between the model name block and the date fields is omitted from the public page.
HITACHI SU8230 SEM DVIA-MB1000 (MB1000_P52) Vibration Survey — Tier-1 Semiconductor — 2017.09.12
Korean worksheet MB1000_P52 for a HITACHI SU8230 SEM at a Tier-1 Semiconductor facility in Daejeon: trip and report metadata, overview, measurement date and operator, site and equipment model, measurement conditions, VC-Class summary table (floor vs platform), narrative summary lines, VC-Class environment plots for Z/X/Y, and MB1000 internal-program transmissibility plots for Z/X/Y. Measurement 2017-09-11; report 2017-09-12; operators Choi, Hyoung Mun (manager) and Kim, Doo Hyun (assistant manager), DAEIL SYSTEMS. Decorative centred banner raster before the printed title block is not republished.

FEI Apreo HiVac DVIA-MB1000 China trip report (P45) — 2017.09.08
MB1000 program P45 handout for an FEI Apreo HiVac at Tianjin University of Science & Technology: checklist, installation result summary table, MB1000 internal-program Z/X/Y plots, vibration-environment Z/X/Y plots, and PASSIVE vs ACTIVE SEM micrographs. The wide banner image placed before the Word title and the large centered photograph directly under the title line are omitted as title-block decoration.

Thermofisher Scientific Apero 2 SEM DVIA-MB1000 Installation Report
Thermofisher Scientific Apreo 2 SEM DVIA-MB1000 Installation

Yangzhou Changelight TESCAN LYRA3 DVIA-MB1000 (MB1000 P44) China installation trip report — 2017.07.20
2017-07-20 worksheet for MB1000 program line P44: TESCAN LYRA3 at a corporate R&D lab on the first floor in Yangzhou (China), FAB vibration-isolation context. Trip 2017-07-18 by Lim Jong-wook; VC-Class summary table, on-site installation photograph, MB1000 internal-program Z/X/Y captures, and vibration-environment Z/X/Y plots are published per DOCX §2a (decorative title-strip image1 omitted).

Tier-1 Electronics Component Manufacturer Suwon facility vibration environment measurement — 2017-07-05
2017 vibration survey at the Tier-1 Electronics Component Manufacturer Suwon site: VC-class summary for floor versus active vibration isolation platform top, plus Z/X/Y 1/3 octave plots with a site photograph.