DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1246 case studies
OMYA ZEISS Gemini DVIA-M1000 (MB1000_P149 / 190816R4) Installation Report — 2020.01.15

DVIA-M1000 field worksheet (internal program MB1000_P149, serial 190816R4) at OMYA with ZEISS Gemini: installation photograph, VC-class summary (Floor vs Above Active), MB1000 internal-program Z/X/Y captures, Octave Band (BASE: Floor, TOP: Above Active), and Auto Spectrum plots. The source form has no separate Vibration specification section, Reference VC diagram upload, or B&K PULSE VC curve set.

SYE Hitachi SU3500 DVIA-MB1000 (MB1000_P135 / 190816R1) Installation Report

DVIA-MB1000 field report (serial 190816R1, internal program MB1000_P135) at SYE with Hitachi SU3500: installation-site photo, VC-class summary table (Floor vs Above Active; criterion cells not filled on the source form), MB1000 internal program captures for Z/X/Y, and octave-band plots (Floor vs Above Active). The source form does not include separate B&K PULSE VC curves, vibration-criterion curve screens, or a Reference section.

Northwest Polytech University ZEISS GeminiSEM 300 DVIA-MB1000 Installation Report (190123R1, 2019-12-16)

MB1000 workbook (isolator worksheet MB1000_190123R1) for ZEISS GeminiSEM 300 at Northwest Polytech University — 1F SEM&TEM room, Qixiang Building; setup 19.12.12, measurement 2019.12.12 (Thursday), report 19.12.16; Operator Choi, Sung Won (DAEIL SYSTEMS). VC-Class summary table, MB1000 internal-program Z/X/Y captures, Octave Band Result (Floor vs Above Active) Z/X/Y in document-insertion order per DOCX embed mapping (see case upload notes). Raster on the centred university masthead/title band is omitted from the public gallery.

Northwest Polytechnical University ZEISS GeminiSEM300 DVIA-MB1000 (P115) trip report — 2019.12.16

China business trip installation worksheet for MB1000 project P115 at Northwest Polytechnical University (1F 126 SEM&TEM Room, Qixiang Building) under ZEISS GeminiSEM300; trip 2019-12-12, report 2019-12-16. Published imagery: MB1000 internal program Z/X/Y screens and vibration-environment measurement Z/X/Y plots (title-block logo raster omitted).

BOSCH TESCAN-MIRA3 DVIA-MB1000 (MB1000 P141 · 190702R5) Internal program worksheet — 2019.12.09

DVIA-MB1000 worksheet for platform serial 190702R5 (program line MB1000 P141 from the issued filename) with TESCAN-MIRA3 at BOSCH site F2: dates and VC-Class summary match the Word extract; MB1000 internal-program Z/X/Y captures and Octave Band Result plots (BASE: Floor, TOP: Above Active) follow DOCX §2a paragraph↔embed mapping (image2–image7 → figure_01–06). The centred banner raster embedded under the MB1000 setup title line (image1) is omitted as decorative.

Hugong Heavy Machinery (沪工重机) ZEISS-EVO18 DVIA-MB1000 (MB1000 P125 / 190531R4) worksheet — 2019.12.09

YIMO-format DVIA-MB1000 worksheet (program line MB1000 P125, isolator serial 190531R4) with target equipment ZEISS-EVO18 at F1, Hugong Heavy Machinery (沪工重机). Operator Choi, Hyoung Mun; setup 2019-12-04; reporting 2019-12-09. Measurement on 2019-12-04 at F1, FIBERHOME R&D CENTER by Daeil System, Manager Choi, Hyoung Mun. Published plots follow DOCX §2a embed mapping: MB1000 internal-program Z, X, and Y (image2–image4) and Octave Band Result (BASE: Floor, TOP: Above Active) Z, X, and Y (image5–image7). Decorative bitmap under “(MB1000_190531R4 Set up)” (image1) is not republished. The source has no Vibration specification, Reference, or Generic Vibration Criteria heading; none were added.