Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1246 case studies
ZOLIX remote tuning — Nanjing University High-power Telescope DVIA-MB1000 (200914R2 P206) — 2020.12.09

ZOLIX-channel MB1000 internal-program worksheet for DVIA-MB1000 serial 200914R2 (platform notation P206) at Nanjing University with High-power Telescope as the stated target equipment. Operator Munho Noh (Daeil System, research engineer); setup, measurement, and reporting on 2020.12.09; business-trip window reproduced verbatim from the Word form. Published figures are the MB1000 internal-program Z/X/Y performance screens plus the transmissibility summary table copied from the form; the title-line header raster (`image1`) is omitted from the public gallery. The source document has no Reference / Generic Vibration Criteria appendix.

YIMO TESCAN DVIA-MB1000 Installation Report — onsite measurement (SN 200521R4, 2020-12-04)

TESCAN tool on DVIA-MB1000 SN 200521R4 — YIMO program, measurement 2020-12-01, report 2020-12-04. Published imagery: on-site TESCAN equipment photo, then MB1000 internal program Z / X / Y plots and transmissibility summary table.

Zili Co., Ltd. Zeiss Sigma 500 DVIA-MB1000 (200715R3-2 · P187) Remote measurement — Internal program plots — 2020.12.02

DVIA-MB1000 serial 200715R3-2 (project P187) for Zeiss Sigma 500 reported via YIMO/channel partner; installation site table lists Shaoxing with END USER 自立股份 (Zili Co., Ltd.). Measurement date and place of measurement are Shaoxing; figures follow Z axis, X axis, and Y axis internal-program screenshots as in Word. The ornamental centered photo immediately under the title block is not republished.

Lemoneyex Bruker SNE-4500M Plus DVIA-L Vibration Measurement Report (P20)

Vibration worksheet dated 2020-11-30 (setup and reporting): Bruker_SNE-4500M Plus at Lemoneyex 4F after active mounting; floor vs above-active VC-class summary (Z/X/Y); UD350 internal-program Z/X/Y screenshots and octave-band floor vs active plots. Generic VC criterion table and VC curve figures from the DOCX are published as the site Reference markdown table only (no separate gallery assets).

Tier-1 Semiconductor Newport I-250 Series DVIA-UD350 P24 Installation Report — Suwon

Compact DVIA-UD350 P24 vibration worksheet at Tier-1 Semiconductor Suwon comparing UD350 TOP vs Newport/PAS TOP on Newport I-250 Series equipment. Setup 20.11.24, report 20.11.25; operator Choi, Hyoung Mun; business trip 17.12.27~17.12.29. Seven figures: on-site UD350 setup and Z/X/Y one-third octave band plots for sequential and simultaneous UD350 vs PAS measurements. Word header ribbon and embedded Generic VC criteria charts omitted.

Tier-1 Semiconductor Sensofar S neox DVIA-UD350 (P24) Installation Report

November 2020 compact UD350 P24 worksheet at Tier-1 Semiconductor (MLCC measurement lab 3F) with Sensofar S neox: setup photo, VC-Class summary (floor A/E/C vs above active F/G/F), UD350 internal-program Z/X/Y captures, octave-band plots (floor vs above active/stage/head and Z-center/Z1–Z4), and Reference as markdown VC criteria only. Word decorative header (image1) and Generic VC criteria artwork (image6, image7) omitted from publication.