Chinese Academy of Sciences — Institute of Physics Thermofisher Helios G5 Beijing DVIA-M1000 (210928R3) Installation Report

Abbreviated DVIA-M1000 worksheet (serial 210928R3, caption M1000_ 210928R3) for the Institute of Physics (CAS) with Thermofisher Helios G5 in BEIJING. The handout includes the VC-class summary table and section titles for the MB1000 internal program and octave-band blocks, but no separate plot bitmaps for those sections in the Word file—only the on-site equipment photograph is published alongside the summary table. The Word signature/decision-table raster tied to the institute header row is omitted from the public page.

Grahope New Materials Technologies Zeiss Sigma300 DVIA-M1000 (211201R9) Internal Program Performance — 2022.07.21

DVIA-M1000 serial 211201R9 — Grahope New Materials Technologies Inc, Zeiss Sigma300, installation measurement in Shenzhen. Handout follows the abbreviated internal-program worksheet; published plots pair with Z axis, X axis, and Y axis per the source. Company-line header graphic and worksheet graphics under Set up are not republished.

GRINM Zeiss EVO15 DVIA-U1000 (220603R1) Installation Report — Beijing

DVIA-U1000 compact installation worksheet (serial 220603R1) at GRINM Resources and Environment Tech. Co., Ltd. with Zeiss EVO15 in Beijing. Reporting 22.07.21 setup 22.07.20 measurement 2022.07.20 (Wednesday) operator Youngha Lee business trip 17.12.27~17.12.29. Publication includes setup photo UB1000 internal‑program plots Z/X/Y octave‑band plots and Active Off/On screens. Decorative header bitmap (combined with cover line image1) omitted.

GRINM Zeiss EVO15 DVIA-UB700 (220603R1) Installation Report
Installation Report
DVIA-ULF Series
07-21-2022

GRINM Zeiss EVO15 DVIA-UB700 (220603R1) Installation Report

DVIA-UB700 worksheet (serial 220603R1) for GRINM Resources and Environment Tech. Co., Ltd., Zeiss EVO15 in Beijing — tuning 22.07.20, report 22.07.21. Summary table (Floor vs Active) plus Z/X/Y VC curves, transmissibility, equipment photo, and active off/on result images; decorative header raster and generic VC figure omitted from the public page per site rules.

Shanghai NIO Automobile ZEISS Sigma300 DVIA-UB1000 (220113R2) Installation Report

DVIA-UB1000/U1000 internal-program worksheet for ZEISS Sigma300 at Shanghai NIO Automobile Co., Ltd (S/N 220113R2). Setup and report dates 22.07.18; business trip line 17.12.27–17.12.29; Overview measurement dated 2022.07.18 (Monday). Publication includes UB1000 internal-program Z / X / Y screenshots only. Decorative company-line header bitmap (image1) omitted. Separate UB700 Sigma300/NIO case publishes transmissibility plots from a different worksheet.

Shanghai NIO Automobile ZEISS Sigma300 DVIA-UB700 (220113R2) Installation Report

DVIA-UB700 (S/N 220113R2) installation report for ZEISS Sigma300 at Shanghai NIO Automobile Co., Ltd. Tuning and report dates 22.07.18; business trip 17.12.27–17.12.29. Publication includes Z / X / Y-axis transmissibility plots from the report. Decorative header bitmap (image1) omitted.