ZEISS Sigma 300 DVIA-MB1000 (P227 / 210503R7) NEMO worksheet — 2022-01-07

NEMO handout MB1000 P227 NEMO 22.01.07.docx — target ZEISS Sigma 300, reporting 22.01.07 (setup 22.01.04). Transmissibility summary at 2/5/10 Hz and MB1000 internal-program Z/X/Y screenshots follow DOCX §2a mapping (rId9–11 → image2–4); the centred title-line ornament (rId8 / image1) is not republished.

Baosteel ZEISS Sigma 300 DVIA-MB1000 (P205) Internal Program Performance — 2021.12.29

DVIA-MB1000 program MB1000 P205 (source MB1000 P205 NEMO 21.12.29.docx) for Baosteel with target equipment ZEISS Sigma 300 at R&D Center 3Floor. Publishes setup field table, Overview, measurement metadata, transmissibility summary at 2/5/10 Hz (Z/X/Y), and MB1000 internal-program plots under Z axis, X axis, and Y axis in DOCX embed order (image2–4). The centered title-line graphic before the setup fields (word/media image1) is omitted from the public page.

Thermofisher Apreo DVIA-MB1000 (211020R5) Installation Report — 2021.12.23

DVIA-MB1000 field worksheet (serial 211020R5, MB1000 P269 line) prepared for Thermofisher Apreo. Dates on the form: setup 21.12.22, reporting 21.12.23, business-trip line 17.12.27~17.12.29. The Overview block and transmissibility summary match the Word table layout; internal-program section title reads “MB1000 internal program performance measurement result” with Z / X / Y axis program screenshots. The title-line setup bitmap under “MB1000 P269 211020R5” (Word image1) is omitted from public copy per installation-report decoration rules.

Carl Zeiss ZEISS-Xradia 620 Versa DVIA-MB3000 (MB3000_P24) Worksheet — Tier-1 Semiconductor — 2021.12.17

DVIA-MB3000 worksheet MB3000_P24 for a Carl Zeiss ZEISS-Xradia 620 Versa installation at a Tier-1 Semiconductor facility (SK 이노베이션, Building 3-2, B1): overview, DAQ settings, VC-class summary versus floor and active platform, field notes, MB3000 internal-program performance graphics (Z/X/Y), and vibration criterion curve captures. Setup 2021.12.16; reporting 2021.12.17; operator Choi, HyoungMun (DAEIL SYSTEMS research engineer).

Huawei (Hitachi) Hitachi SU8200 DVIA-MB1000 (210601R1 / P251) Internal Program Performance — Shanghai — 2021.12.07

DVIA-MB1000 P251 serial 210601R1 — field handout MB1000 internal program measurements for Huawei (Hitachi) with Hitachi SU8200 SEM in Shanghai, 2021.12.07. Operator Kim, Doohyun; onsite trip dates 2021.12.27–2021.12.29 recorded on the sheet. Source plots follow Z axis, X axis, and Y axis headings (§2a: image1–3). Decorative header/table layout outside these figures was not separately republished.

3Trees Coatings Thermo Scientific Apreo 2C DVIA-MB1000 (210705R2) Internal Program Performance — 2021-11-29

DVIA-MB1000 internal-program handout for Thermo Scientific Apreo 2C at 三棵树涂料股份有限公司 (3Trees Coatings), serial 210705R2. Embedded equipment photograph and Z/X/Y transmissibility plots match DOCX §2a heads (platform title line, Z axis, X axis, Y axis). Setup 2021-11-25; report written date 2021-11-29.