Skip to main content

Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1246 case studies
Helios 5 DVIA-M1000 Bengbu Installation Report (NORINCO GROUP / 220127R6)

Abbreviated DVIA-M1000 handout dated 2022-10-04 — NORINCO GROUP · Helios 5 · Bengbu. Publishes the three-axis MB1000 internal program performance plots from the DOCX.

Zeiss Sigma300 DVIA-M1000 Installation Report (XINSTEEL / Xinyu, 220812R3, 2022)

DVIA-M1000 220812R3 with Zeiss Sigma300 at Xinyu — cover summary, set-up photograph, VC-class summary table, MB1000 internal-program Z/X/Y screens, and octave-band Z/X/Y results.

CSOT Wuhan HELIOS 5 UC DVIA-ML1000 Installation Report (220401R2, 2022-09-28)

CSOT Wuhan — HELIOS 5 UC on DVIA-M1000 (SN 220401R2). MB1000 internal program plots and octave-band results.

SNU Precision DVIA-UB350 (220727R3) Installation Report — Asan
Installation Report
DVIA-ULF Series
09-21-2022

SNU Precision DVIA-UB350 (220727R3) Installation Report — Asan

DVIA-UB350 (S/N 220727R3) installation report for SNU Precision headquarters (Asan): first setup noise from stage motion resolved by replacing 70 kg springs with 180 kg springs, followed by second setup and vibration measurement 2022-09-21. Published VC-curve and transmissibility plots (before/after adjustment) for Z/X/Y axes, spring-replacement summary tables, and PULSE 22 measurement setup notes; decorative title-block bitmap (image1) and Generic Vibration Criteria figure (image17) omitted — Reference uses the site VC criterion markdown table.

Jiangsu Modern Road & Bridge Axia ChemiSEM HiVac DVIA-M1000 (220718R3) Installation Report — Nanjing

DVIA-M1000 worksheet for serial 220718R3 (source M1000_220718R3_22.09.19.docx). END USER Jiangsu Modern Road & Bridge · Axia ChemiSEM HiVac in Nanjing. Setup/reporting dated 22.09.19 per the form with operator Yu, Ho Sang; measurement session 2022.09.19 (Monday) recorded as printed. Publication includes installation photograph under the setup title row, VC-Class Floor vs Above Active summary, MB1000 internal-program transmissibility/coherence screenshots, and octave-band spectra. Decorative signature-block raster on the company-header line was omitted.

Tier-1 Semiconductor Hitachi FE SEM DVIA-UB1000 (180305R3) Installation Report — Icheon

DVIA-UB1000 (serial 180305R3, 1140×910×224H mm) installation report at Tier-1 Semiconductor, icheon-si for Hitachi FE SEM equipment — tuned 2022-09-07 by Seounghoon Cheon (DAEIL SYSTEMS), reported 2022-09-14. Measurement with Data Physics Quattro / SignalCalc ACE; FFT 0–80 Hz, Hanning / 800 lines. VC summary (equipment off): Floor vs Active across Z/X/Y bands as in the Measurement Summary table. Publishes equipment-off Floor / Top VC and Transmissibility plots (nine figures). Decorative cover header bitmap omitted; ISO/VC reference chart replaced with markdown table.