Skip to main content

Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

Filtered Case Studies

441 case studies
Foxconn ZEISS Sigma 500 DVIA-MB1000 (200522R2-5 · P159) Remote measurement — Internal program plots — 2020.11.19

Remote worksheet for DVIA-MB1000 serial 200522R2-5 (project P159) with ZEISS Sigma 500; END USER and installation site list Foxconn. Operator Munho Noh (Daeil System); setup, measurement, and reporting on 2020-11-19. Published figures are MB1000 internal-program Z / X / Y axis screenshots only (DOCX §2a). The Word handout has no Reference / Generic Vibration Criteria block.

Guangdong Technion-Israel Institute of Technology FEI Helios 5 UC DVIA-MB1000 (200522R2-7 · P171) Remote measurement — Internal program plots — 2020.11.19

DVIA-MB1000 serial 200522R2-7 (project P171) for FEI Helios 5 UC; END USER appears on the worksheet as Guangdong Israel Institute of Technology (Israel Tech, 以色列理工) with Guangdong Province as the stated installation region. Operator Munho Noh (Daeil System, research engineer); setup and reporting 20.11.19; Measurement date block 20.11.19 (Thursday) lists Guangdong as Place of measurement. The worksheet includes Transmissibility table values at 2 Hz / 5 Hz / 10 Hz plus three MB1000 internal-program screenshots in Z/X/Y axis order. Decorative JPEG under the centred “MB1000_… (P171) Set up” banner is not republished.

Southern University of Science and Technology FEI Volumescope2 DVIA-MB1000 (191129R6 · P151) Remote measurement — Internal program plots — 2020.11.02

DVIA-MB1000 serial 191129R6 (project P151) remote worksheet via /channel partner at Southern University of Science and Technology in Shenzhen. Target equipment and Equipment Model both read FEI Volumescope2 per the Word form. Published plots follow Z axis, X axis, and Y axis; the ornamental photo under the centered setup heading is not republished.

Wangxiang ZIESS EVO18 DVIA-MB1000 (170906R4 · P50) Internal program worksheet — 2020.10.21

DVIA-MB1000 internal-program worksheet (platform serial 170906R4, program line MB1000 P50) for ZIESS EVO18 with end user Wangxiang campany in Hangzhou. Operator Doohyun Kim (Daeil System); setup 2020-10-20, measurement 2020-10-20, reporting 2020-10-21; the Overview line, transmissibility summary at 2 / 5 / 10 Hz, and Signal-program captures for Z, X, and Y follow the DOCX verbatim. The large centred graphic directly under the Word title line is omitted as a title-block decorative image.

Wangxiang ZEISS Sigma 300 DVIA-MB1000 MB1000 Internal Program (P179) — 2020.10.21

MB1000 program worksheet 200522R2-3 (P179) for ZEISS Sigma 300 in Hangzhou: setup summary tables, transmissibility summary at 2 / 5 / 10 Hz, and Signal-program internal performance captures for Z, X, and Y. The large centered graphic placed directly under the Word title line is omitted from the public page as a title-block decorative image.

Tier-1 Semiconductor FEI TF20 TEM DVIA-MB3000 (200623R1) Installation Worksheet — 2020.10.21

DVIA-MB3000 (serial 200623R1) active-mount vibration worksheet after TF20-FEI TEM installation at Tier-1 Semiconductor. Measurement date 2020.10.21; internal-program Z/X/Y transmissibility and coherence plots plus installation photograph; summarized frequency picks at 2 Hz, 5 Hz, and 10 Hz with omnidirectional assessment.