LIVE CELL IMAGING MICROSCOPE
NIKON DS-Qi2 + OLYMPUS U-CMAD3 + U-TV1X-2 Live Cell Imaging Microscope installed on Custom DVIA-UD 350

NSK Guangzhou Zeiss Sigma300 UB1000 P17 Remote Tuning Installation Report (210325R6, 2021-10-13)
UB1000 (S/N 210325R6, P17 remote tuning worksheet) vibration check after active mounting on Zeiss Sigma300 at guangzhou for END USER 恩斯克. Operator Kim, Doohyun; setup and reporting 2021-10-13. Publication includes transmissibility summary at 2 / 3 / 10 Hz (Z/X/Y) and UB1000 internal-program Z/X/Y axis plots; decorative title-block JPEG (image1) omitted.

Hitachi S-4800 UB1000 P24 Remote Tuning Installation Report (210302R1, 2021-08-26)
UB1000 (S/N 210302R1, P24 remote tuning worksheet) vibration check after active mounting on HITACHI-S 4800, delivered. Operator CHOI HYOUNGMUN; setup 2021-08-25; report 2021-08-26. Publication includes the UB1000 setup photograph, 10 Hz transmissibility summary (Z/X/Y), and UB1000 internal-program Z/X/Y axis plots.

Institute for Basic Science Main Building Ultrasonic Equipment DVIA-UD350 P29 Pulse Worksheet Installation Report
May 2021 B&K PULSE 14 worksheet at Institute for Basic Science (main building, 2F) after active mounting of ultrasonic equipment on DVIA P29: VC-Class Floor vs Above Active summary table, UD350 internal-program Z / X / Y screenshots, and octave-band Floor vs Above Active plots. Pulse VC auxiliary captures (DOCX images 5–6) and orphaned media 2–4 omitted in favour of the summary table; the source form has no Reference section.

Institute for Basic Science Main Building Ultrasonic Equipment DVIA-UD350 P28 Pulse Worksheet Installation Report
May 2021 B&K PULSE 14 worksheet at Institute for Basic Science (main building, 2F) after active mounting of ultrasonic equipment on DVIA P28: VC-Class Floor vs Above Active summary table, UD350 internal-program Z / X / Y screenshots, and octave-band Floor vs Above Active plots. Generic VC reference rasters embedded under the title block (DOCX image5–6) are omitted because the source has no Reference section.

Nanfu Battery Hitachi SU1000 FlexSEM 1000II DVIA-UB350 (201021R4 P1) Remote-Tuning Report
Channel remote-tuning handout (21.02.22) for DVIA-UB350s set 201021R4(P1) under Hitachi SU1000 FlexSEM 1000II at Nanping city, 4F end user 南孚电池. Operator Munho Noh; business trip 17.12.27–17.12.29. Transmissibility at 2 Hz and 10 Hz is tabulated; three MB1000 UI–style internal-program displays are published for Z, X, and Y axes. The JPEG under the title line before the summary tables is omitted as a title-block graphic.