Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
Filtered Case Studies

Avaryholding HUAIAN Olympus Dsx 1000 DVIA-UD350-0910M (220603R2) Installation Report
DVIA-UD350-0910M-50t-800H (S/N 220603R2) compact installation worksheet at Avaryholding (HUAIAN) with Olympus Dsx 1000: site checklist, operator and trip dates, Overview with on-site measurement metadata (2023.01.04), and UD350 internal-program Z / X / Y axis screenshots. Decorative Word header bitmap (image1) and Pause Mode UI popup (image4) omitted; no Reference section in the source.
XZZJS ZEISS SEM DVIA-UB700 (200828R3) Installation Report — Xuzhou
DVIA-UB700 desktop active isolation (S/N 200828R3) installation report prepared for XZZJS with ZEISS SEM in Xuzhou, China. Tuning on 2022-12-13; report dated 2022-12-19. Publication includes Transmissibility (Z/X/Y — DOCX repeats the Z-axis embed under X-axis labeling) plus equipment photograph. Decorative header/logo bitmap (Word image1 / rId8) omitted.

XZZJS ZEISS SEM DVIA-U1000 (200828R3) Installation Report — Shanghai
DVIA-U1000 compact installation worksheet (serial 200828R3) for END USER XZZJS with ZEISS SEM; installation Shanghai, measurement Xuzhou. Setup 22.12.13, reporting 22.12.19, business trip 17.12.27~17.12.29. Overview measurement dated 2022.12.13 (Tuesday). Publication includes setup photograph and U1000 internal-program Z / X / Y axis screenshots. Decorative header artwork from the report cover block is omitted.
Tier-1 Semiconductor Icheon Hitachi FE SEM DVIA-UB1000 Installation Report
DVIA-UB1000 (S/N 180305R3) installation report at Tier-1 Semiconductor Icheon with Hitachi FE SEM Equipment. Tuning 29 Nov 2022; report written 30 Nov 2022. Floor vs active VC curves and transmissibility for vertical, left-to-right, and front-to-back axes with equipment turned off. Generic vibration criteria published as a markdown Reference table only.

LG Digital Park (Pyeongtaek) DVIA-UD700 (220513R1) Installation Report
DVIA-UD700 (S/N 220513R1, 1400×1000×390H) installation report prepared for LG Digital Park (Pyeongtaek); optical development equipment (광학관련 개발장비); engineers Seounghoon Cheon and Yongha Lee. Tuning date 22.10.31 and report written date 22.11.03 per worksheet. Summary VC-class table (Floor vs Active) and nine Data and Image plots measured with equipment turned off—floor/top VC curves and transmissibility for Z/X/Y; decorative header bitmap (image1) and Reference VC diagram (image11) omitted in favor of the published markdown criteria table.

Shanghai Synchrotron Radiation Facility DVIA-UB700 (211026R3-3) Installation Report
DVIA-UB700 Installation Report (serial 211026R3-3) prepared for Shanghai Synchrotron Radiation Facility; engineer Hosang Yu; tuning October 27, 2022; report written November 2, 2022. Location Shanghai, China; equipment TBD on the form. Overview states the DVIA-UB700 active vibration isolation platform is appropriately installed and functioning as intended. Published figures are Z / X / Y-axis Transmissibility plots and one equipment image. Decorative Word header bitmap (image1) omitted.