RIYUE HEAVY INDUSTRY EVO10 NINGBO DVIA-U1000-910×1140 mm (220512R5, UB700 form) Installation Report
Compact DVIA-U1000 (910×1140 mm plate, serial 220512R5) installation worksheet for RIYUE HEAVY INDUSTRY with EVO10 at NINGBO. Tuning 23.03.03, written 23.03.07; business-trip line 17.12.27~17.12.29. Z / X / Y-axis internal-program transmissibility plots plus an equipment photograph; omitted non-informative decorative header raster.

FUJIAN ZI JIN TONG BO Axia ChemiSEM LoVac DVIA-UB700 Installation Report (220718R11)
Formal DVIA-UB700 installation report worksheet (serial 220718R11) for Axia ChemiSEM LoVac at FUJIAN ZI JIN TONG BO — Z / X / Y axis Transmissibility plots and installation photograph from the UB700 report dated 2023.03.07 line. Decorative cover bitmap from the DOCX (image1.PNG) omitted. Distinct companion to the DVIA-U1000 internal program screenshots case with the same serial.

China Electric Power Research Institute Sigma500 DVIA-U1000 (220512R4) Installation Report — Beijing
DVIA-U1000 compact installation worksheet (serial 220512R4) for CHINA ELECTRIC POWER RESEARCH INSTITUTE with Sigma500 in Beijing. Setup and reporting 23.01.31, business-trip line 17.12.27~17.12.29; Overview measurement dated 2023.01.31 (Tuesday). Publishes setup photograph and Z / X / Y internal-program performance screenshots. Decorative address-banner bitmap (image1) omitted.

China Electric Power Research Institute Sigma500 DVIA-UB700 (220512R4) Installation Report — Beijing
DVIA-UB700 installation report prepared for CHINA ELECTRIC POWER RESEARCH INSTITUTE (serial 220512R4), Beijing site, Sigma500 equipment. Tuning date and report written date 23.01.31 per the report header; business-trip line dated 17.12.27~17.12.29. Published figures are Z / X / Y-axis transmissibility plots and one equipment photograph. The DOCX-only address-banner graphic (daeilsys site line) tied to document image1 is omitted as decorative header imagery.

KIST Olympus IX51 DVIA-UD350-1008M Installation Report
DVIA-UD350-1008M-50t-750H (S/N 221004R1) installation report at KIST (Seoul): Floor and active-platform VC curves plus transmissibility with equipment turned off.

KIST Olympus IX51 DVIA-UD350-1008M (221004R2) Installation Report
DVIA-UD350-1008M-50t-750H (S/N 221004R2) installation report at KIST (Seoul): tuned January 10, 2023 by Seounghoon Cheon (DAEIL SYSTEMS), reported January 12, 2023. Olympus IX51 microscope; Data Physics Quattro / SignalCalc ACE measurement. Summary VC-class table (Floor vs Active) and nine equipment-off Floor / Top VC and Transmissibility plots (Z/X/Y). Decorative header bitmap (image1) and Reference VC diagram (image11) omitted; Reference uses the standard markdown criteria table.