Tier-1 Electronics Component Manufacturer Busan FCB PSP DVIA-P2200 (230417R6) Installation Report — 2024-04-17

DVIA-P2200 (serial 230417R6) set-up and vibration measurement at the Tier-1 Electronics Component Manufacturer Busan site FCB building 3F for FCB PSP unit 1, after relocation (tuning 2024-04-17; report written 2024-04-18). Engineers Jongwon Park and Chaewon Lee (DAEIL SYSTEMS). Equipment specification VC-B; equipment installed/IDLE. Published plots: vertical, left-to-right, and front-to-back VC curves and transmissibility (six figures). Reference uses the standard Generic Vibration Criteria markdown table only.

Hainan University Thermo Fisher Spectra 300 DVIA-MB3000 (231004R3-1) Installation Report

DVIA-MB3000 abbreviated internal-program worksheet for serial 231004R3-1 (source MB3000_231004R3-1_24.04.15.docx). Target equipment Thermo Fisher Spectra 300 for Hainan University (海南大学) in Hainan (海南); date of setup 24.04.15 and date of reporting 24.07.05 per the form; operator Byeonghun Cho in the header block; measurement dated 2024.04.15 (Monday) with operator Chaewon Lee from DAEIL SYSTEMS. Overview uses the standard DVIA-MB3000 wording; no vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. Internal-program plots follow the Vertical, Left to Right, and Front to Back captions. The JPEG directly under `(MB3000_ 231004R3-1 Set up)` was treated as decorative title-block artwork and omitted from the public page.

Hainan University Thermo Fisher Spectra 300 DVIA-MB3000 (231113R4-1) Installation Report — 2024.04.15

DVIA-MB3000 internal-program worksheet for serial 231113R4-1 (source MB3000_231113R4-1_24.04.15.docx) at Hainan University with Thermo Fisher Spectra 300; measurement dated 2024.04.15 (Monday); header operator Lee, Chaewon (worksheet spelling); Overview uses the standard DVIA-MB3000 wording followed by measurement lines and trailing “5.” as in the form; setup 24.04.15 and reporting 24.07.05. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in this form. The JPEG under `(MB3000_ 231113R4-1 Set up)` is condensed handout header art and was omitted from the public page.

Thermo Fisher Scientific Spectra 300 TEM DVIA-MB3000 Installation Report

Thermo Fisher Spectra 300 DVIA-MB3000 Installation

Thermo Fisher Scientific Spectra 300 TEM DVIA-MB3000 Installation Report

Thermo Fisher Spectra 300 DVIA-MB3000 Installation

Hallym University JEOL JBX-8100FS DVIA-PB2200 Installation Report

DVIA-PB2200 (serial 220926R2) SET-UP and vibration measurement at Hallym University Chuncheon cleanroom (C/R) with JEOL JBX-8100FS during equipment installed/Idle state (2nd tuning). Publishes equipment vibration specification graphics, VC curves and transmissibility by axis, and multi-band measurement summary table.