Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

Wuxi Photon Park NX20 DVIA-M1000 MB1000 Internal Program Report
Wuxi Photon (Wuxi) — Park NX20 on DVIA-M1000 (MB1000 handout 231214R7-2). Publishes the site equipment photograph plus MB1000 internal-program Vertical, Left to Right, and Front to Back results (measurement dated 2024.05.21).

Hainan University Thermo Fisher Spectra 300 DVIA-MB3000 (231004R3-1) Installation Report — 2024.05.09
DVIA-MB3000 abbreviated internal-program worksheet for serial 231004R3-1 (source MB3000_231004R3-1_24.05.09.docx). Target equipment Thermo Fisher Spectra 300 for Hainan University (海南大学) in Hainan (海南); date of setup 24.05.09 and date of reporting 24.07.05 per the form; operator Lee, Chaewon in the header block; measurement dated 2024.05.09 (Thursday); overview uses the DVIA-MB3000 wording and lists Operator as DAEIL SYSTEMS Chaewon Lee in the worksheet line order. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. Internal-program plots follow Vertical, Left to Right, and Front to Back. The JPEG under `(MB3000_ 231004R3-1 Set up)` was treated as decorative title-block artwork and omitted from the public page.

Thermo Fisher Scientific Spectra 300 TEM DVIA-MB3000 Installation Report
Thermo Fisher Spectra 300 DVIA-MB3000 Installation

Hitachi SU7000 DVIA-M1000 (230818R3) Donghua University Setup Handout
Short setup handout for serial 230818R3 (DVIA-M1000 wording per source) with Hitachi SU7000 at Donghua University. Reporting lists operator Chaewon Lee, setup and reporting 24.05.07, and business-trip dates 17.12.27~17.12.29. Overview states the platform is appropriately installed and functioning as intended. Measurement note dated 2024.05.07 (Tuesday) with operator DAEIL SYSTEMS Chaewon Lee; place of measurement and installation site Shanghai (上海); equipment HITACHI SU7000. Published imagery: equipment photo on the DVIA-ML platform base plus M1000 internal program Vertical, Left to Right (two captures), and Front to Back plots.

Hainan University Thermo Fisher Spectra Ultra DVIA-MB3000 (231004R3-3) Installation Report
DVIA-MB3000 abbreviated worksheet for serial 231004R3-3 with Thermo Fisher S/TEM Spectra Ultra at Hainan University in Hainan. Setup dated 24.04.18 and reporting dated 24.07.05; header operator Byeonghun Cho; measurement dated 2024.04.18 (Thursday) with operator DAEIL SYSTEMS Byeonghun Cho. Overview uses the standard DVIA-MB3000 sentence. No vibration specification, equipment condition, tuning request, measurement summary table, or Reference section appears in the source. Internal-program captures are labeled Vertical, Left to Right, and Front to Back under “M3000 internal program performance measurement result.” The JPEG under the Set-up title line was treated as decorative and omitted from the public page.

Thermo Fisher Scientific Spectra Ultra DVIA-MB3000 Installation Report
Thermo Fisher Spectra Ultra DVIA-MB3000 Installation