Korea Institute of Science and Technology (KIST) Microscope DVIA-UD350 (220127R1-2) Installation Report

DVIA-UD350 (SN 220127R1-2) at KIST Building L7 Room 7223, Seongbuk-gu, Seoul, supporting a microscope. Engineers Youngha Lee and Seounghoon Cheon (DAEIL SYSTEMS); tuning and report dated April 21, 2022. Measurement summary table plus Z/X/Y VC curves (Floor and Active), transmissibility plots, and VC criteria as markdown (header decoration image and Word Reference raster omitted).

LIVE CELL IMAGING MICROSCOPE
Case Study
DVIA-ULF Series
04-12-2022

LIVE CELL IMAGING MICROSCOPE

NIKON DS-Qi2 + OLYMPUS U-CMAD3 + U-TV1X-2 Live Cell Imaging Microscope installed on Custom DVIA-UD 350

UB1000 P24 (200828R4) ZEISS Sigma 300 remote tuning measurement report

UB1000 vibration isolation serial 200828R4 setup and measurement handout (path) for target equipment ZEISS Sigma 300 at a Tier-1 Semiconductor account. Setup and reporting dated 22.01.10 with operator CHOI, HYOUNGMUN; business-trip reference 17.12.27–17.12.29; overview measurement 22.01.10 (Mon). Publication includes the UB1000 internal-program setup screen plus distinct Z / X / Y performance captures, and transmissibility summary at 5 Hz and 10 Hz. Fields left blank on the handout appear as N/A. Reference publishes the Generic Vibration Criteria markdown table only (no supplementary diagram).

UB1000 P26 (210720R4) ZEISS Sigma 300 remote tuning measurement report

UB1000 vibration isolation serial 210720R4 setup report under the target ZEISS Sigma 300 microscope (path). Setup and measurement documentation dated January 2022: transmissibility summary at 5 Hz and 10 Hz for vertical, lateral, and cross-lateral axes, plus UB1000 internal program performance captures for Z, X, and Y. Fields left blank on the handout appear as N/A. Reference publishes the Generic Vibration Criteria markdown table only (no supplementary diagram).

NSK Guangzhou Zeiss Sigma300 UB1000 P17 Remote Tuning Installation Report (210325R6, 2021-10-13)

UB1000 (S/N 210325R6, P17 remote tuning worksheet) vibration check after active mounting on Zeiss Sigma300 at guangzhou for END USER 恩斯克. Operator Kim, Doohyun; setup and reporting 2021-10-13. Publication includes transmissibility summary at 2 / 3 / 10 Hz (Z/X/Y) and UB1000 internal-program Z/X/Y axis plots; decorative title-block JPEG (image1) omitted.

Hitachi S-4800 UB1000 P24 Remote Tuning Installation Report (210302R1, 2021-08-26)

UB1000 (S/N 210302R1, P24 remote tuning worksheet) vibration check after active mounting on HITACHI-S 4800, delivered. Operator CHOI HYOUNGMUN; setup 2021-08-25; report 2021-08-26. Publication includes the UB1000 setup photograph, 10 Hz transmissibility summary (Z/X/Y), and UB1000 internal-program Z/X/Y axis plots.