Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
Filtered Case Studies

KIST Microscope DVIA-UD350 Inspection Report
DVIA-UD350 (S/N 220127R1-2) inspection report at KIST (Seoul L7223): PULSE 22 VC curves, UI-program transmissibility, summary plot, and installation photo after a service visit for screen shake during ambient walking.

China Merchants Testing Vehicle Technology Research Institute Co., Ltd. ZEISS FE-SEM Sigma360 DVIA-U1000 (230328R5) Installation Report — Chongqing
DVIA-U1000 compact worksheet (serial 230328R5) for ZEISS FE-SEM Sigma360 at China Merchants Testing Vehicle Technology Research Institute Co., Ltd. in Chongqing. Setup 24.01.08, reporting 24.01.16; measurement 2024.01.08 (Monday); operator Park, Jongwon; business trip 17.12.27~17.12.29. Publication includes U1000 internal-program Z/X/Y screenshots only—the issued Word file has no separate equipment setup raster.

whchem Huaian Sensofar s neox DVIA-UD350-0911M-50t-800H (231019R3) Installation Report
DVIA-UD350-0911M-50t-800H (S/N 231019R3) compact installation worksheet at whchem (Huaian) with Sensofar s neox: setup photo and UD350 internal-program Z / X / Y axis screenshots. Decorative Word header bitmap (image1) omitted from publication.

ARCHE Semilab AFM-2000 DVIA-UB350 (220621R1) Inspection Report
DVIA-UB350 (serial 220621R1) inspection report for Semilab AFM-2000 at ARCHE (147, Annyeong-gil, Byeongjeom-gu, Hwaseong-si). Tuning date 23.11.21; report 23.11.22. Idle-state and AFM-operation vibration summary tables, Z/X/Y transmissibility and VC-curve plots; Korean field notes on VC levels and suspected 60 Hz electrical noise on X during AFM. Decorative header graphic omitted; Reference uses the standard VC criteria markdown table only.

ARCHE Semilab AFM-2000 DVIA-UB350 Inspection Report
DVIA-UB350 (S/N 220621R1) active vibration isolation platform inspection report for Semilab AFM-2000 installed at ARCHE (147, Annyeong-gil, Byeongjeom-gu, Hwaseong-si, Gyeonggi-do). Z / X / Y-axis Transmissibility and VC-Curve measurements taken in idle state and with AFM in operation. All three axes achieve VC-G on the DVIA-UB350 in idle; X-axis shows suspected 60 Hz electrical noise during AFM operation.

Hefei Institutes of Physical Science (CAS) Sigma300 DVIA-U1000 (230515R1) Installation Report — Hefei
DVIA-U1000 compact worksheet (serial 230515R1) for ZEISS Sigma300 at Hefei Institutes of Physical Science, Chinese Academy of Sciences. Setup and reporting 23.09.11–23.09.15; measurement 2023.09.11 (Monday); operator Lee, Youngha; business trip 17.12.27~17.12.29. Published U1000 internal-program Z/X/Y screenshots only—the issued Word file has no separate equipment setup raster after the omitted header banner, no Octave Band / Active Off–On plots, and no separate Reference VC figure.