YIMOTECH Hitachi SU8600 FE-SEM DVIA-ML1000 Installation Report
YIMOTECH Hitachi High-Tech SU8600 FE-SEM DVIA-ML1000 installation report — following installation of the DVIA-ML1000 active vibration isolation platform at Wuxi, tuning and vibration measurement were performed with the equipment in the IDLE state. Measured against the horizontal and vertical allowable vibration specification, both the floor and the DVIA-ML1000 platform passed on the vertical, left-to-right, and front-to-back axes. The tuning request work-order form, per-axis Autospectrum plots, and the installation photo are published.

YIMOTECH Yidon Technologies YF-1801 FE-SEM DVIA-ML1000 Installation Report
YIMOTECH Yidon Technologies YF-1801 FE-SEM DVIA-ML1000 installation report — following installation at Suzhou for end user Yidong Optical Technology, the DVIA-ML1000 active vibration isolation platform was tuned and measured with the equipment in the IDLE state. Across the vertical, left-to-right, and front-to-back axes the DVIA-ML1000 platform reached VC-G on all three axes. The tuning request work-order form, per-axis Autospectrum and VC Curves plots, and the installation photo are published.

Tier-1 Electronics Component Manufacturer BGA-PSP DVIA-P2200 Installation Report
Tier-1 electronics component manufacturer Sejong P5 3F Clean Room BGA-PSP plating-thickness gauge DVIA-P2200 installation report — tuning and vibration measurement with the equipment installed and Turned off; VC-B specification met on all axes for both floor and the DVIA-P2200 platform.

Ansteel Iron and Steel Research Institute Thermo Scientific Talos TEM DVIA-ML3000 (251125R4) Installation Report
DVIA-ML3000 (S/N 251125R4) installation report at Ansteel Iron and Steel Research Institute in Anshan, China — Thermo Scientific TEM Talos, supplied through YIMO TECH. Published figures: the tuning request work order and the vertical / left-to-right / front-to-back VC curves obtained via the UI program, plus the onsite installation photo. Vibration specification is 1.56 µm/s RMS horizontal and 3.12 µm/s RMS vertical over 1-100 Hz; the Measurement Summary cites See Section 9, with all three axes FAIL on the floor and PASS on the DVIA-ML3000 platform.

YOUSHIZE TECH ZEISS GeminiSEM 360 FIB-SEM DVIA-ML1000 Installation Report
YOUSHIZE TECH ZEISS GeminiSEM 360 FIB-SEM DVIA-ML1000 installation report — following installation at Yancheng for end user Yancheng High-tech Zone, the DVIA-ML1000 active vibration isolation platform was tuned and measured with the equipment in the IDLE state, with the floor and the DVIA-ML1000 platform both passing on the vertical, left-to-right, and front-to-back axes. The tuning request, vibration specification, per-axis Autospectrum plots, and the installation photo are published.

YIMO TECH Thermo Fisher Scientific Apreo 2S SEM DVIA-ML1000 Installation Report
YIMO TECH Thermo Fisher Scientific Apreo 2S SEM DVIA-ML1000 installation report — following installation at Shizuishan for end user Ningxia Orient Tantalum Industry Co. Ltd., the DVIA-ML1000 active vibration isolation platform meets the VC-F vibration specification (the floor fails on vertical, left-to-right, and front-to-back, while the DVIA-ML1000 platform passes all three axes). The tuning request form, per-axis VC Curves, and the installation photo are published.